Error Code

Message Information

 

 

Details

FlexAddress is not implemented in one of the versions of

 

 

firmware. Please update the firmware.

 

Action

Check firmware versions. Update CMC 1 and CMC 2

 

 

firmware to match.

SWC5001

Message

<name> upgrade failed.

 

 

Action

Reboot the system and attempt the upgrade again.

TMP0100

Message

The system board <name> temperature is less than the lower

 

 

 

warning threshold.

 

LCD Message

System board <name> temperature is outside of range.

 

Details

Ambient air temperature is too cool.

 

Action

Check the system operating environment.

TMP0101

Message

The system board <name> temperature is less than the lower

 

 

 

critical threshold.

 

LCD Message

System board <name> temperature is outside of range.

 

Details

Ambient air temperature is too cool.

 

Action

Check the system operating environment.

TMP0102

Message

The system board <name> temperature is greater than the

 

 

 

upper warning threshold

 

LCD Message

System board <name> temperature is outside of range.

 

Details

Ambient air temperature is too warm or one or more fans

 

 

may have failed.

 

Action

The system board <name> temperature is outside of the

 

 

optimum range. Check the fans.

TMP0103

Message

The system board <name> temperature is greater than the

 

 

 

upper critical threshold.

 

LCD Message

System board <name> temperature is outside of range.

 

Details

Ambient air temperature is too warm or one or more fans

 

 

may have failed.

 

Action

The system board <name> temperature is outside of the

 

 

optimum range. Check the fans.

137

Page 137
Image 137
Dell M820 owner manual SWC5001 Message, TMP0100 Message, TMP0101 Message, TMP0102 Message, TMP0103 Message