Error Code | Message Information |
|
| Action | Reboot the management controller or iDRAC. Cycle system |
|
| input power. If problem persists call support. |
SEL1204 | Message | An unknown system hardware failure detected. |
| ||
| LCD Message | Unknown system hardware failure. |
| Details | If the system event log failed to initialize platform status and |
|
| failure events are not captured. Some management software |
|
| will not report platform exceptions. |
| Action | |
|
| issues persists, contact support. |
SEL1209 | Message | The platform event filter action failed. |
| ||
| Details | System policies or permissions may prevent the action from |
|
| executing. If configured, the system does not execute the |
|
| action on a platform event (such as power down, cycle, |
|
| interrupt, and send alert). |
| Action | Review platform event configuration. |
SEL1211 | Message | The |
| ||
| Details | The time stamp on system event log events may not |
|
| correlate to the system time. |
| Action | Cycle system input power. If problem persists, contact |
|
| support. |
SEL1300 | Message | No bootable media found. |
| ||
| Details | System setup displays the system boot order. The local video |
|
| screen may also show additional information. (IPMI sensor |
|
| type code 1eh - offset 00h). |
| Action | Check system boot settings. Check if mass storage controller |
|
| configuration settings are applicable. |
SEL1302 | Message | |
| ||
| Details | The disk in the drive is not formatted correctly or does not |
|
| contain the necessary operating system files. |
| Action | Replace diskette with a bootable disk. |
SEL1304 | Message | The PXE server not found. |
|
134