Error Code Message Information
Action Reboot the management controller or iDRAC. Cycle system
input power. If problem persists call support.
SEL1204 Message An unknown system hardware failure detected.
LCD Message Unknown system hardware failure.
Details If the system event log failed to initialize platform status and
failure events are not captured. Some management software
will not report platform exceptions.
Action Re-configure system to minimum supported configuration. If
issues persists, contact support.
SEL1209 Message The platform event filter action failed.
Details System policies or permissions may prevent the action from
executing. If configured, the system does not execute the
action on a platform event (such as power down, cycle,
interrupt, and send alert).
Action Review platform event configuration.
SEL1211 Message The time-stamp clock could not be synchronized.
Details The time stamp on system event log events may not
correlate to the system time.
Action Cycle system input power. If problem persists, contact
support.
SEL1300 Message No bootable media found.
Details System setup displays the system boot order. The local video
screen may also show additional information. (IPMI sensor
type code 1eh - offset 00h).
Action Check system boot settings. Check if mass storage controller
configuration settings are applicable.
SEL1302 Message Non-bootable diskette detected.
Details The disk in the drive is not formatted correctly or does not
contain the necessary operating system files.
Action Replace diskette with a bootable disk.
SEL1304 Message The PXE server not found.
134