Error Code

Message Information

 

 

Details

The removed device may be necessary for proper operation.

 

 

System functionality may be degraded.

 

Action

If removal was unintended, check presence of the removed

 

 

device, then reinstall or reconnect

HWC3002

Message

Server <number> is removed.

 

 

Action

If removal was unintended, check presence of the server,

 

 

then reinsert.

HWC3004

Message

IO module <number> is removed.

 

 

Action

If removal was unintended, check presence of the IO

 

 

module, then reinsert.

HWC4000

Message

A hardware incompatibility detected between BMC/iDRAC

 

 

 

firmware and CPU.

 

LCD Message

Incompatibility between BMC/iDRAC firmware and CPU.

 

 

Update firmware.

 

Details

A hardware incompatibility was detected between BMC/

 

 

iDRAC firmware and Processor(s). An iDRAC or BMC

 

 

firmware update is needed.

 

Action

Update the BMC/iDRAC firmware. If the issue persists, see

 

 

Getting Help.

HWC4002

Message

A hardware incompatibility detected between BMC/iDRAC

 

 

 

firmware and other hardware.

 

Details

A hardware incompatibility was detected between BMC/

 

 

iDRAC firmware and other hardware. An iDRAC or BMC

 

 

firmware update is needed.

 

Action

Update the BMC/iDRAC firmware. If the issue persists, see

 

 

Getting Help.

HWC4011

Message

Hardware unsuccessfully updated for mezzanine card

 

 

 

<number>.

 

Action

Check presence of the hardware, reinstall or reconnect, then

 

 

reattempt the update. If the issue persists, see Getting Help.

HWC4013

Message

Hardware unsuccessfully updated for embedded NIC.

 

101

Page 101
Image 101
Dell M820 owner manual HWC3002 Message, HWC3004 Message, HWC4000 Message, HWC4002 Message, HWC4011 Message, HWC4013 Message