Error Code

Message Information

 

PCI1302

Message

A bus time-out was detected on a component at bus

 

 

 

<bus>device<device>function <func>.

 

Details

System performance may be degraded. The device has failed

 

 

to respond to a transaction.

 

Action

Cycle input power, update component drivers, if device is

 

 

removable, reinstall the device.

PCI1304

Message

An I/O channel check error was detected.

 

 

LCD Message

I/O channel check error detected. Power cycle system.

 

Action

Cycle input power, update component drivers, if device is

 

 

removable, reinstall the device.

PCI1306

Message

A software error was detected on a component at bus

 

 

 

<bus>device<device>function <func>.

 

Action

Reboot the system and update the component drivers.

PCI1308

Message

A PCI parity error was detected on a component at bus

 

 

 

<bus>device<device>function <func>.

 

LCD Message

PCI parity error on bus <bus> device <device> function

 

 

<func>. Power cycle system.

 

Details

System performance may be degraded, PCI device may fail

 

 

to operate, or system may fail to operate.

 

Action

Cycle input power, update component drivers, if device is

 

 

removable, reinstall the device.

PCI1310

Message

A PCI system error was detected on a component at bus

 

 

 

<bus>device<device>function <func>.

 

LCD Message

PCI system error on bus <bus> device <device> function

 

 

<func>. Power cycle system.

 

Details

System performance may be degraded, or system may fail to

 

 

operate.

 

Action

Cycle input power, update component drivers, if device is

 

 

removable, reinstall the device.

PCI1314

Message

A bus correctable error was detected on a component at bus

 

 

 

<bus>device<device>function <func>.

 

Details

System performance may be degraded.

111

Page 111
Image 111
Dell M820 owner manual PCI1302 Message, PCI1304 Message, PCI1306 Message, PCI1308 Message, PCI1310 Message, PCI1314 Message