Error Code

Message Information

 

 

VLT0102

Message

Processor module <name> voltage is greater than the upper

 

 

 

warning threshold.

 

LCD Message

Processor module <name> voltage is outside of range.

 

Details

System hardware detected an over voltage or under voltage

 

 

condition.

 

 

If multiple voltage exceptions occur consecutively the

 

 

system may power down in fail-safe mode.

 

Action

1.

Review system logs for power supply exceptions.

 

 

 

 

2.

Remove the processor module. Inspect processor

 

 

 

socket for bent pins.

 

 

3.

If the issue persists, see Getting Help.

VLT0103

Message

Processor module <name> voltage is greater than the upper

 

 

 

critical threshold.

 

LCD Message

Processor module <name> voltage is outside of range.

 

Details

System hardware detected an over voltage or under voltage

 

 

condition.

 

 

If multiple voltage exceptions occur consecutively the

 

 

system may power down in fail-safe mode.

 

Action

1.

Review system logs for power supply exceptions.

 

 

 

 

2.

Remove the processor module. Inspect processor

 

 

 

socket for bent pins.

 

 

3.

If the issue persists, see Getting Help.

VLT0104

Message

Processor module <name> voltage is outside of the

 

 

 

allowable range.

 

LCD Message

Processor module <name> voltage is outside of range.

 

Details

System hardware detected an over voltage or under voltage

 

 

condition.

 

 

If multiple voltage exceptions occur consecutively the

 

 

system may power down in fail-safe mode.

 

Action

1.

Review system logs for power supply exceptions.

 

 

 

 

2.

Remove the processor module. Inspect processor

 

 

 

socket for bent pins.

 

 

3.

If the issue persists, see Getting Help.

143

Page 143
Image 143
Dell M820 owner manual VLT0102 Message, VLT0103 Message, VLT0104 Message