Error Code Message Information
Details The memory may not be seated correctly, misconfigured, or
has failed.
Action Check the memory configuration. Re-seat the memory
modules. If the issue persists, see Getting Help.
MEM7002 Message A hardware mismatch detected for memory riser.
LCD Message Memory riser mismatch detected. Check memory riser.
Details Memory riser is installed incorrectly, or failed.
Action Check that the memory riser is installed correctly. If the issue
persists, see Getting Help.
MEM8000 Message Correctable memory error logging disabled for a memory
device at location <location>.
LCD Message SBE log disabled on <location>. Re-seat memory.
Details Errors are being corrected but no longer logged.
Action Review system logs for memory exceptions. reinstall
memory at location <location>.
OSE0000 Message A critical stop occurred during OS load.
Details The system halted due to an exception during operating
system load or operating system initialization.
Action Review operating system logs and system video for
additional information.
OSE0001 Message A runtime critical stop occurred.
Details The system halted due to an exception while the operating
system was running. This is a kernel panic or bug check
event.
Action Review operating system logs and system video for
additional information.
OSE0004 Message A soft shut-down initiated by platform event filter.
Details A separate exception or status condition shutdown the
operating system. (IPMI sensor type 20h - offset 04h).
Action Review system event log for platform events capable of
shutting the system down.