Error Code

Message Information

 

 

Details

The memory may not be seated correctly, misconfigured, or

 

 

has failed.

 

Action

Check the memory configuration. Re-seat the memory

 

 

modules. If the issue persists, see Getting Help.

MEM7002

Message

A hardware mismatch detected for memory riser.

 

 

LCD Message

Memory riser mismatch detected. Check memory riser.

 

Details

Memory riser is installed incorrectly, or failed.

 

Action

Check that the memory riser is installed correctly. If the issue

 

 

persists, see Getting Help.

MEM8000

Message

Correctable memory error logging disabled for a memory

 

 

 

device at location <location>.

 

LCD Message

SBE log disabled on <location>. Re-seat memory.

 

Details

Errors are being corrected but no longer logged.

 

Action

Review system logs for memory exceptions. reinstall

 

 

memory at location <location>.

OSE0000

Message

A critical stop occurred during OS load.

 

 

Details

The system halted due to an exception during operating

 

 

system load or operating system initialization.

 

Action

Review operating system logs and system video for

 

 

additional information.

OSE0001

Message

A runtime critical stop occurred.

 

 

Details

The system halted due to an exception while the operating

 

 

system was running. This is a kernel panic or bug check

 

 

event.

 

Action

Review operating system logs and system video for

 

 

additional information.

OSE0004

Message

A soft shut-down initiated by platform event filter.

 

 

Details

A separate exception or status condition shutdown the

 

 

operating system. (IPMI sensor type 20h - offset 04h).

 

Action

Review system event log for platform events capable of

 

 

shutting the system down.

109

Page 109
Image 109
Dell M820 owner manual MEM7002 Message, MEM8000 Message, OSE0000 Message, OSE0001 Message, OSE0004 Message