Error Code

Message Information

 

 

 

LCD Message

Memory module <number> <name> voltage is outside of

 

 

range.

 

Details

System hardware detected an over voltage or under voltage

 

 

condition.

 

 

If multiple voltage exceptions occur consecutively the

 

 

system may power down in fail-safe mode.

 

Action

1.

Review system logs for power supply exceptions.

 

 

 

 

2.

Re-configure the system to minimum configuration,

 

 

 

inspect and reinstall system cables.

 

 

3.

If the issue persists, see Getting Help.

VLT0228

Message

The memory module <name> voltage is outside of range.

 

 

LCD Message

Memory module <number> <name> voltage is outside of

 

 

range.

 

Details

System hardware detected an over voltage or under voltage

 

 

condition.

 

 

If multiple voltage exceptions occur consecutively the

 

 

system may power down in fail-safe mode.

 

Action

1.

Review system logs for power supply exceptions.

 

 

 

 

2.

Re-configure the system to minimum configuration,

 

 

 

inspect and reinstall system cables.

 

 

3.

If the issue persists, see Getting Help.

VLT0230

Message

The mezzanine card <number> <name> voltage is less than

 

 

 

the lower warning threshold.

 

Details

System hardware detected an over voltage or under voltage

 

 

condition.

 

 

If multiple voltage exceptions occur consecutively the

 

 

system may power down in fail-safe mode.

 

Action

1.

Review system logs for power supply exceptions.

 

 

 

 

2.

Re-seat the mezzanine card.

 

 

3.

If the issue persists, see Getting Help.

VLT0231

Message

The mezzanine card <number> <name> voltage is less than

 

the lower critical threshold.

152

Page 152
Image 152
Dell M820 owner manual VLT0228 Message, VLT0230 Message, VLT0231 Message