Error Code

Message Information

 

 

Action

Check system video and review event log for additional

 

 

information.

PST0256

Message

POST fatal error detected.

 

 

LCD Message

POST fatal error detected.

 

Details

System BIOS detected a functional or configuration issue

 

 

during system POST.

 

Action

Check system video and review event log for additional

 

 

information.

PSU0001

Message

Power supply <number> failed.

 

 

LCD Message

PSU <number> failed. Check PSU.

 

Action

Remove and reinstall the power supply. If the issue persists,

 

 

see Getting Help.

PSU0002

Message

A predictive failure detected on power supply <number>.

 

 

LCD Message

Predictive failure on PSU <number>. Check PSU.

 

Details

System performance and power redundancy may be

 

 

degraded or lost.

 

Action

Remove and reinstall the power supply at the next service

 

 

window. If the issue persists, see Getting Help.

PSU0003

Message

The power input for power supply <number> is lost.

 

 

LCD Message

Power input for PSU <number> is lost. Check PSU cables.

 

Details

The power supply is installed correctly but an input source is

 

 

not connected or is not functional.

 

Action

Verify the input source is attached to the power supply.

 

 

Verify the input power is within the operating requirements

 

 

for the power supply.

PSU0004

Message

The power input for power supply <number> is outside of

 

 

 

the allowable range.

 

LCD Message

Power input for PSU <number> is outside of range. Check

 

 

PSU cables.

 

Details

The operating requirements for the power supply may be

 

 

found in this manual or on the power supply itself.

122