Model HHC-990

5-2. ERROR CODES AND

 

 

 

WARNINGS (Continued)

 

 

 

 

 

 

 

 

 

Display

 

Cause

Panel Board Correction

E-6B

AIR TEMP SENSOR

• Faulty air temperature

• Turn switch to OFF position, then back to

 

FAILED SHORTED”

 

probe

ON; if the display shows “E-6”, the

 

 

 

 

temperature probe should be checked;

 

 

 

 

once the temperature probe is repaired, or

 

 

 

 

replaced, the controls should return to

 

 

 

 

normal; if “E-6”persists, have PC board

 

 

 

 

replaced

 

 

 

 

 

“E-12A

WATER HEATER

Faulty water

• Turn switch to OFF position, then back to

 

SENSOR FAILED

 

heater probe

ON; if the display shows “E-12A”, the

 

OPEN”

 

 

water heater should be checked and

 

 

 

 

repaired or replaced (the water heater

 

 

 

 

probe is built into the water heater); the

 

 

 

 

controls should return to normal; if

 

 

 

 

“E-12A” persists, have PC board replaced

 

 

 

 

 

“E-12B

WATER HEATER

Faulty water

• Turn switch to OFF position, then back to

 

SENSOR FAILED

 

heater probe

ON; if the display shows “E-12B”, the

 

CLOSED”

 

 

water heater should be checked and

 

 

 

 

repaired or replaced (the water heater

 

 

 

 

probe is built into the water heater); the

 

 

 

 

controls should return to normal; if

 

 

 

 

“E-12B” persists, have PC board replaced

 

 

 

 

“E-17

HUMIDITY SENSOR

• Faulty humidity sensor

• Turn switch to OFF position, then back to

 

FAILED”

 

 

ON; if the display shows “E-17”, the

 

 

 

 

humidity sensor should be checked;

 

 

 

 

once the humidity sensor is repaired, or

 

 

 

 

replaced, the controls should return to

 

 

 

 

normal; if “E-17” persists, have PC board

 

 

 

 

replaced

 

 

 

 

“E-18

NO WATER, FLOAT

• Float switch stuck or

• Turn switch to OFF position, then back to

 

SWITCH FAILED”

 

faulty; faulty relay

ON; if the display shows “E-18”, check

 

 

 

(stuck on);water pan

and clean float switch; clean water pan;

 

 

 

needs cleaned;

have relay and water heater sensor

 

 

 

loose or faulty water

checked and replace if necessary; tighten

 

 

 

heater sensor; acorn nuts

acorn nuts on water heater cover; make

 

 

 

on water heater cover

sure 2 complete pieces of insulation are

 

 

 

loose, or water heater

under the water heater cover; if “E-18”

 

 

 

insulation missing or

persists, have PC board replaced

 

 

 

damaged

 

A humidity error only shuts down the humidity system. If a humidity error occurs, and you want to use the cabinet without humidity, turn the humidity off by following the directions for SP-4, Humidity Setpoint, in Special Programming Section of this manual. Once the setpoint is off, the alarm stops, but the error code shows in display. (Includes “E-12A”, “E-12B”, “E-17” and “E-18”).

4-8

804

Page 25
Image 25
Henny Penny HHC-997, HHC-990, HHC-993, HHC-992, HHC-996, HHC-998 manual AIR Temp Sensor

HHC-996, HHC-992, HHC-993, HHC-990, HHC-997 specifications

Henny Penny has long been a trusted name in the foodservice equipment industry, particularly known for its innovative line of pressure fryers. Among its most popular offerings are models HHC-998, HHC-997, HHC-990, HHC-993, and HHC-992. Each model showcases advanced technologies, enhanced features, and unique characteristics that cater to varying culinary needs.

The HHC-998 is recognized for its exceptional speed and efficiency. Designed with advanced pressure frying technology, it reduces cooking times significantly while delivering moist, flavorful results. Its digital control system allows operators to set precise cooking times and temperatures, ensuring consistent quality, which is crucial for high-volume kitchens. The HHC-998 also features robust construction and easy cleaning designs, enhancing its longevity and ease of use.

Next is the HHC-997, which is highly regarded for its user-friendly interface. This model includes an intuitive touchscreen control panel that simplifies the frying process. The HHC-997 employs a high-performance heating system to ensure rapid recovery times, minimizing downtime between cooking batches. Additionally, its energy-efficient design assists in lowering operational costs, making it a smart investment for busy restaurants.

The HHC-990 is tailored for establishments that prioritize food safety and compliance. This model is equipped with an innovative temperature monitoring system that alerts operators of any deviations, thus ensuring food is cooked to perfection every time. Its stainless steel exterior provides durability and ease of maintenance, while the interior is designed to allow for quick cleaning, enhancing kitchen hygiene.

The HHC-993 combines versatility with performance, accommodating a wide range of menu items. This fryer can handle everything from chicken to fish and vegetables. Its adjustable pressure settings give operators the flexibility to fine-tune cooking processes based on specific recipes. Moreover, it boasts advanced filtration systems that extend oil life and improve flavor consistency.

Lastly, the HHC-992 stands out with its compact design, making it ideal for kitchens with limited space. Despite its size, it maintains high cooking capacities, allowing for efficient food preparation without sacrificing quality. The model's energy management system optimizes energy consumption while achieving rapid cooking times.

In conclusion, Henny Penny's line of pressure fryers, including the HHC-998, HHC-997, HHC-990, HHC-993, and HHC-992, showcases the company’s commitment to innovation, efficiency, and quality. Each model is designed to meet specific operational needs while ensuring delicious, consistently cooked food that keeps customers coming back.