1. Introduction
The TH147 and TH148LE thermostats can be used to control:
•a gas, fuel oil or electric furnace - 2 or 3 wires
•a central air conditioner - 2 or 3 wires
•a hot water system with or without pump - 2 wires
•a millivolt system - 2 wires
•a central heating and cooling system - 4 or 5 wires
Attention: These thermostats are not compatible with heat pumps or
Adjustment
Displaybuttons
Backlight button
|
|
|
| |
|
|
|
| |
System operating |
|
| ||
Fan operating | ||||
mode selector | ||||
mode selector | ||||
|
|
Functions | TH147 | TH148LE |
|
| |
|
|
|
Heating/cooling control | X | X |
|
|
|
Fan control | X | X |
Programmable cycle lengths | X | X |
|
|
|
Temperature display in °C or °F | X | X |
|
|
|
Backlit display | X | X |
Battery replacement indicator | X | X |
|
|
|
Unoccupied mode activated remotely (requires Aube’s CT240) |
| X |
|
|
|
Interchangeable faceplates (titanium, charcoal & taupe) |
| X |
2. Installation
Note: The installation must be performed by an electrician or a qual- ified installer.
2.1 Removing the Old Thermostat
IN ORDER TO AVOID ANY RISK OF ELECTRIC SHOCK, CUT POWER TO THE HEATING/COOLING SYSTEM.
nRemove the old thermostat to access the wires.
Attention: If the old thermostat was mounted onto an electrical box, it might have been powered by 120/240 volts. In this case, the TH147 or TH148LE thermostat cannot be used.
oIdentify and label each wire (with the corresponding letter on the wire terminal) and remove it from its terminal.
p If necessary, strip the end of each wire (maximum of 6 mm).
q Wrap the wires around a pencil to prevent them from falling into the wall.
r If the hole in the wall is too big, insulate it using a
2.2 Installing the New Baseplate
For a new installation, choose a location approximately 1.5 m (5 feet) above the floor and on an inside wall. Avoid draughty areas (top of staircase, air outlet, etc.), dead air spots (behind doors), direct sunlight or areas near concealed pipes or chim- neys.
nRemove the thermostat faceplate.
oLoosen the locking screw in order to separate the thermostat from its baseplate (the screw cannot be completely removed).
pGently tilt the thermostat upwards.
qMark and bore the appropriate mounting holes (or use the existing holes). Insert the plastic anchors.
rPass the wires through the opening of the baseplate and fix the baseplate to the wall using the screws provided.