TO REDUCE THE RISK OF SEVERE INJURY OR DEATH: READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS!
WARNING
ITEM # PART# DESCRIPTION QUAN.
1 Operator Power Head 1
2 Track Rails 2
7 006031 3/8-16 Keps Hex Nut 6
8 101315 3/8 - 16 X 6-1/2 Hex Head Blot 1
9 107049 Track Bracket AR
10 006034 1/2 - 15 Hex Nut 2
11 006049 1/2 Split Lockwasher 2
12 106265 Front Idler Assembly 1
13 Chain For Track Rail 1
14 3 Piece Chain Connecting Link 1
15 006084 Chain Tension Adjustment Bolt 1
16 006031 3/8 - 16 Keps Hex Nut 2
17 100512 Track Trolley 1
—— AR - As Required
ITEM # PART# DESCRIPTION QUAN
18 005031 3 Button Station 1
19 100513 Release Door Arm 1
20 100236 Extension Door Arm 2
21 100235 Curved Door Arm 1
22 100108 Door Bracket 1
23 100469 Hardware Pkg Com. Door Arm 1
26 3/8 - 16 X 2-1/2 Carriage Bolt 2
16 3/8 - 16 X 1 Hex Head Bolt 1
27 3/8 Nylon Insert Locknut 1
28 5/16 - 18 X 1-1/4 Hex Head Bolt 4
29 5/16 - 18 Keps Hex Nuts 4
25 100468 Hardware Pkg Com. Track Assy 1
4 3/8 - 16 Hex Nut AR
5 3/8 Split Lockwasher AR
6 3/8 - 16 X 1-1/2 Hex Head Bolt AR
Install only on a properly balanced garage
door. An improperly balanced door could cause
severe injury. Have a qualified service person
make repairs to cables, spring assemblies and
other hardware before installing the opener.
Remove all ropes and remove or make
inoperative all locks (unless mechanically and/or
electrically interlocked to the power unit) that are
connected to the garage door before installing the
opener.
Lightweight doors (fiberglass, aluminum etc.)
must be reinforced to avoid door damage. Check
the door manufacturer’s instruction manual for a
bracing procedure or the availability or a
Reinforcement Kit. See Page 9.
Model AUD-S is a Commercial Vehicular
Door Operator and as such IS NOT recommended
for pedestrian traffic. In installations where it is
known that pedestrians will be nearby ensure a
pedestrian door is available for entrance and exit
to the building. In addition YOU MUST install an
auxiliary entrapment protection device (reversing
door edge or photoelectric beam device).
Connect an auxiliary entrapment protection
device (reversing edge or photoelectric device
across the door opening). a device of this type is
STRONGLY ADVISED FOR ALL commercial
operator installations. An auxiliary entrapment
protection device is REQUIRED when the three
button control station is out of sight of the door
or any other automatic or manual control is
used.
Install the opener at least 8 feet or more
above the floor.
Do not connect the opener to the source of
power until instructed to do so.
Locate the control station:
a) within sight of the door and;
b) at a minimum height of five feet above
the floor and;
c) away from all moving parts of the door.
Do not overtighten the clutch adjustment to
compensate for a poorly working door.
Securely attach any WARNING signs or
placards to either the door or above the control
station as directed.
After installing the opener, all safety features
must be tested for proper operation (see page
19).
COMPONENT IDENTIFICATION LISTING 5 IMPORTANT INSTALLATION WARNINGS