Audiovox GMRS1202 TechnicalSpecifications, Troubleshooting, Main Channel Frequencies

Models: GMRS1202 GMRS120

1 2
Download 2 pages 9.42 Kb
Page 2
Image 2

VOX Selection Mode

Warning

TechnicalSpecifications

This option enables you to have hands-free conversation.

Your voice or nearby sound is detected and the radio transmits without the need to press the PTT button.

To set radio for VOX operation,

-From GMRS/FRS standby mode, press and hold the MODE button until the VOX icon appears on the display.

VOX can be turned off by pressing the MODE button for 3 seconds.

• Do not operate the transceiver unless you are licensed to do so.

• Remove the batteries from the transceiver if it is not expected to

be used for long periods. This will eliminate the possibility of

chemicals leaking from the batteries and corroding the transceiver.

• Avoid exposing the transceiver to water or extremes of temperature.

• Do not use this device in or near a mining facility, which uses

General Frequency Range:

Channels 1 through 7 are shared with FRS radios.

Channels 8 through 14 are FRS only.

Channels 15 through 22 are GMRS only.

Refer to frequency chart on next page.

Refer to frequency chart on next page.

Refer to frequency chart on next page.

90 DAY LIMITED WARRANTY

Applies to Audiovox Family Radio and General Mobile Service Products.

AUDIOVOX CORPORATION (the Company) warrants to the original retail purchaser of this product that should this product or any part thereof, under normal use and conditions, be proven defective in material or workmanship within 90 days from the date of original purchase, such defect(s) will be repaired or replaced with new or reconditioned product (at the Company's option) without charge for parts and repair labor.

To obtain repair or replacement within the terms of this Warranty, the product is to be delivered with proof of warranty coverage (e.g. dated bill of sale), specification of defect(s),

Channel Scan Operation

This feature allows you to monitor all channels automatically for valid signals. While scanning, you can transmit and receive. When a signal is received, the scan is interrupted and will return to scan mode 5 seconds after reception is terminated.

NOTE:

While the scan function is active,the MODE button will be inoperative. The scan mode will reduce the overall battery life due

to the battery save function is overridden. To enable the channel scan mode,

-From GMRS/FRS standby mode,momentarily press the power Button; (SCAN) will appear on the LCD display.

-The radio will display each channel (1-22) in order as the scan mode operates to find an active main channel.

-When unit doesn't find any signals and you want to transmit, press the PTT switch to return to home channel operation.

The transceiver will automatically resume scanning approximately 5 seconds after the communication is completed.

-If there is no activity and you want to leave the scan mode,

press the power button momentarily and the unit will return to normal operation; (SCAN) icon will disappear from the LCD display.

remotely triggered explosives or in areas labeled “Blasting Area”.

Premature or accidental detonation may result.

• Do not attempt to modify or in any way increase the output of this

transceiver. Its output is designed to meet the legal limits set

by the FCC.

• Do not use this device or change its batteries in potentially

explosive atmospheres as sparks in such areas could result

in an explosion.

• Turn your transceiver off wherever posted notices restrict the use

of radios or cellular telephones. Facilities such as hospitals may use equipment that is sensitive to RF energy.

Turn your transceiver off on board aircraft when requested to do so. Do not place your radio in front of a vehicle’s air-bag.

If the air-bag deploys, it could propel the transceiver like a projectile causing bodily injury.

Channel Spacing

12.5kHz

Dimensions (W x H x D)

1.73 W x 3.3 H x 1.10 D

(Without Antenna)

(44.0 mm x 84.0 mm x 28.0 mm)

PowerSupply

 

Power Source

Alkaline Batteries, AAA (3), 4.5 VDC

Operating Time

30 hours Low Power

(Transmit: Receive: Standby = 5: 5: 90 ratio)

Receiver

 

Useable Sensitivity

>-119 dBm

Maximum Audio Output Power

> 0.25 Watt maximum (32 Ohm )

Modulation Distortion

< 5% (1 kHz 70%)

Transmitter

 

RF Output Power

0.5 Watts maximum

Maximum Deviation

+/- 2.5 kHz

Modulation Distortion

< 5% (1 kHz 70%)

This transceiver complies with FCC regulations for use in the United States of America. Use in other countries may be prohibited or restricted by local regulation.Please check with the local regulating agency before using this device outside the United States of America.

transportation prepaid, to the warranty center at the address shown below. The Company disclaims liability for communications range of this product.

This Warranty does not apply to any product or part thereof which, in the opinion of the Company, has suffered or been damaged through alteration, improper installation, mishan- dling, misuse, neglect, accident, or by removal or defacement of the factory serial number/ bar code label(s). THE EXTENT OF THE COMPANY'S LIABILITY UNDER THIS WARRANTY IS LIMITED TO THE REPAIR OR REPLACEMENT PROVIDED ABOVE AND, IN NO EVENT, SHALL THE COMPANY'S LIABILITY EXCEED THE PURCHASE PRICE PAID BY PURCHASER FOR THE PRODUCT.

This Warranty is in lieu of all other express warranties or liabilities. ANY IMPLIED WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY, SHALL BE LIMITED TO THE DURATION OF THIS WRITTEN WARRANTY. ANY ACTION FOR BREACH OF ANY WARRANTY HEREUNDER INCLUDING ANY IMPLIED WARRANTY OF MER- CHANTABILITY MUST BE BROUGHT WITHIN A PERIOD OF 30 MONTHS FROM DATE OF ORIGINAL PURCHASE. IN NO CASE SHALL THE COMPANY BE LIABLE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY, EXPRESS OR IMPLIED, WHATSOEVER. No person or representative is authorized to assume for the Company any liability other than expressed herein in connection with the sale of this product.

Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damage so the above limitations or exclusions may not apply to you. This Warranty gives you specific legal rights and you may also have other rights which vary from state to state.

AUDIOVOX ELECTRONICS CORP., 150 MARCUS BLVD., HAUPPAUGE, NEW YORK 11788

1-800-290-6650

128-5385B

Key Tone

This feature allows the transceiver to sound a confirmation tone whenever the following keys are pressed: Up/Down button, MODE button, SCAN button. The key tone is always on.

Roger Beep Tone

The Roger Beep is a tone which is automatically transmitted whenever the PTT button is released. This tone alerts the receiving party that the transmission has been terminated intentionally.

To enable and disable the Roger Beep tone:

-From GMRS/FRS standby mode, press the Function Button until the flashing Roger Beep icon appears with On or oF.

-Press the Up or Down Button to select the tone on or off as desired.

- When enabled, the tone icon ( ) appears steady on the display. - Press the PTT to confirm selection.

Battery Alert

When the battery icon () blinks on/off at 7 second intervals, as shown on the LCD panel, recharge or install fresh batteries.

NOTES FOR GOOD COMMUNICATION

1.The GMRS120/120-2 22 channels are shared on a ‘take turns’ basis. This means other groups may be talking on any of the channels.

A common code of ethics/courtesy is to switch to another vacant channel and not to attempt to talk over someone who is already using the channel you first selected.

Troubleshooting

Problem

Possible cause

Correction

No transmission

Weak batteries

Charge or replace batteries

while pressing

Incorrect battery polarity

Install the batteries

the PTT Button

 

following the directions in

 

 

paragraph Installing the

 

 

Batteries.

Weak or no

Weak batteries

Charge or replace batteries

signal received

Channel and privacy

Adjust the transceiver's

 

code not set the same

settings to match those

 

settings of the target

 

as target transceiver

 

transceiver

 

 

 

Volume level too low

Increase volume level

 

PTT Button inadvertently

 

Release PTT Button

 

depressed

 

 

 

 

 

 

Excessive radio interference

Change to a different

 

channel

 

on a particular channel

 

Avoid operating in or near

 

Obstruction of radio signal

 

large buildings or vehicles

Unit beeps, but

Batteries extremely

Charge or replace batteries

will not function

discharged

 

when turned on

 

 

 

Main Channel Frequencies

 

CHANNEL

FREQ(MHz)

 

 

/TYPE

/PWR

 

1

GMRS/FRS

462.5625

12

2

GMRS/FRS

462.5875

13

3

GMRS/FRS

462.6125

14

4

GMRS/FRS

462.6375

15

5

GMRS/FRS

462.6625

16

6

GMRS/FRS

462.6875

17

7

GMRS/FRS

462.7125

18

8

FRS

467.5625

19

9

FRS

467.5875

20

10

FRS

467.6125

21

11

FRS

467.6375

22

CHANNEL

/TYPE

FRS

FRS

FRS

GMRS

GMRS

GMRS

GMRS

GMRS

GMRS

GMRS

GMRS

FREQ(MHz)

/PWR

467.6625

467.6875

467.7125

462.5500

462.5750

462.6000

462.6250

462.6500

462.6750

462.7000

462.7250

2.The GMRS120/120-2 has been designed to maximize performance and improve transmission range in the field. To avoid interference, it is recommended that you do not use the units closer than

5 feet apart.

3.For best transmission results, always keep your mouth about 2-3 inches from the microphone (5) and speak slowly

in a normal voice.

4.To increase battery life, avoid features such as Scan. These features will reduce operating time considerably.

Reception of

Interference from

Turn the devices off or move

electronic device such

unwanted signals

farther away from them.

as computers or TVs

NOTE : Channels 1 through 7 are shared with FRS radios. Channels 8 through 14 are FRS only.

Channels 15 throuhg 22 are GMRS only.

Page 2
Image 2
Audiovox GMRS1202 owner manual TechnicalSpecifications, Troubleshooting, Main Channel Frequencies