18
How to Perform A Leak Test “FIRST TIME USE” and as required
Supplies Needed for a Leak Test:
• Clean paint brush
• Water
• Dish washing liquid
1. Use an LP Gas Cylinder equipped with an OPD (Overfill Prevention Dev ice) and have it filled at an authorized LP
gas dealer by a qualified attendant.
2. Make sure all grill Control Panel Knobs are turned to the “Off” position and ver ify that the LP Gas Cylinder valve is
closed by turning the knob on the LP Gas Cylinder clockwise until it s tops.
3. Mix one part of water with one part of dish washing liquid.
4. Figures 1, 2, 4 and 4a show the grill at assembly step 9, prior to attaching the Side Tables, and illustrate the initial
steps in the “FIRST TIME USE LE AK TEST”.
Detach the Control Panel from the Grill Body/Firebox by removing the two 5/32” Bolts from each en d. (Fig. 1) Gently
pull the Control Panel away from the Body until Valves disengage from the Tubular burner ends. (Fig. 2) Support
the Control Panel to keep tension off of the igniter wire leads or detach the wire leads from the Star ter Button
module.
To reduce the risk of a laceration hazard:
• Wear protective gloves when removing or replacing Control p anel, which could have sharp edges.
CAUTION
!
5. With the regulator hose connected to the LP Gas Cylinder, turn the knob on the Cylinder counterclock wise. (Fig. 3)
Fig. 3
Fig. 1 Fig. 2
Tubular B urner
Ends
Coupling Nut Check for leaks at
Cylinder Valve and
Regulator Connection
and Fittings
Fig. 3a