Avalon Stoves Indoor Fireplace manual 0Installation

Models: Indoor Fireplace

1 40
Download 40 pages 9.27 Kb
Page 10
Image 10

1 0Installation

Clearances

Insert must be placed so that no combustibles are within, or can swing within (e.g. drapes, doors), 36" of the front of the heater.

Insert must be placed a minimum 8-3/4" from a side wall (or combustible protruding more than 3/4").

Mantel Requirements

The mantel must meet the requirements shown in the illustration to the right.

12”

The mantel must fall within this shaded area (or above). Maximum mantel depth is 12”.

Hearth Requirements

The non-combustible hearth must extend 6” to the front and sides of the firebox opening (you must open the door to measure).

Facing Requirements

38”

The non-combustible facing must extend 7" to the side and 6" above the hopper lid.

Placing the Insert

The insert must be placed within an undamaged masonry or factory built (metal) fireplace. Loose bricks or other damage must

be fixed. Clean the fireplace before installing.

3-1/2”

33”

Side Wall

Min. 8-3/4"

Apply the "This fireplace has been altered..." sticker to the fireplace. You may wish to place it in a location where it will be covered by the surround panels.

The vent should be routed to the fireplace prior to installing the insert. See the section "Vent Installation" for details on vent location.

Use the leveling bolts for fireplaces with recessed floors (included with the insert). Screw them into the baseplate from below.

13-1/4"

Place the insert so the back edge of the baseplete extends 13-1/4" into the fireplace.

Run the power cord to the side along the front of the fireplace (do not route it under the insert).

Travis Industries

4 0 5 0 5 2 5

1 0 0 - 0 1 1 4 4

Page 10
Image 10
Avalon Stoves Indoor Fireplace manual 0Installation