6Specifications
Heating Specifications:
Approximate Maximum Heating Capacity (in square feet)* | 800 to 2,250 |
Burn Rate (Pounds per Hour)** | 1.7 to 5.5 |
Maximum Burn Time on Low Burn** | 28 to 52 Hours |
Hopper Capacity (based upon hopper extension position) | 48 to 89 Pounds |
*Heating capacity will vary depending on the home's floor plan, degree of insulation, and the outside temperature. It is also affected by the fuel size, quality, and moisture level.
**Small pellets will increase or decrease the stated burn rates and burn times. Differences of plus or minus 20% depending on fuel quality may occur.
Dimensions:
Center of 4” diameter Flue is
32”
See “Hopper Extension
| 45” |
| |
|
|
| |
|
|
| Fireplace Opening |
12" | |||
|
|
| Door Opening |
Electrical Specifications: |
| ||
Electrical Rating | 115 Volts, 3.6 Amps, 60 Hz | ||
Watts During | 400 (approximately) | ||
Watts During Operation | 180 (approximately) |
Fuel:
•This heater is designed and approved for pelletized wood fuel or a mixture up to 50% corn, 50% pellets. See page 23 for details on using a corn pellet mix.
EPA Compliance:
This heater is EPA exempt from Phase II requirements, but has been tested for emissions using EPA test methods by OMNI Test Labs.
Travis Industries | 4 0 5 0 5 2 5 | 1 0 0 - 0 1 1 4 4 |