2.2 Absolute Maximum Ratings
| Parameter |
|
| Symbol |
|
| Minimum |
|
| Maximum |
|
| Units |
|
|
|
|
|
|
|
|
|
|
| |||||
Power Supply |
| VCC |
| 5.5 |
|
| V | |||||||
|
|
|
|
|
|
|
|
| ||||||
Operating Temperature |
| VOT | 0 |
| 50 |
|
| °C | ||||||
|
|
|
|
|
|
|
|
| ||||||
Storage Temperature |
| VST |
| 70 |
|
| °C | |||||||
|
|
|
|
|
|
|
|
| ||||||
Relative Humidity |
| HRH | 10 |
| 80 |
|
| RH | ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Stresses greater than those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress rating only and functional operation of the device at these or any other conditions above those indicated in the operations section for extended periods of time may affect reliability.
2.3 Signal Pin Assignment
Transmitter / Receiver
Pin | Signal Assignment | Pin | Signal Assignment |
1 | T.M.D.S. Data2+ | 11 | T.M.D.S Clock Shield |
|
|
|
|
2 | T.M.D.S. Data2 Shield | 12 | T.M.D.S Clock - |
|
|
|
|
3 | T.M.D.S. Data2- | 13 | CEC |
|
|
|
|
4 | T.M.D.S. Data1+ | 14 | No Connect |
|
|
|
|
5 | T.M.D.S. Data1 Shield | 15 | SCL |
|
|
|
|
6 | T.M.D.S. Data1- | 16 | DSA |
|
|
|
|
7 | T.M.D.S. Data0+ | 17 | DDC/CEC Ground |
|
|
|
|
8 | T.M.D.S. Data1 Shield | 18 | +5V Power |
|
|
|
|
9 | T.M.D.S. Data0- | 19 | Hot Plug Detect |
|
|
|
|
10 | T.M.D.S Clock + |
|
|
|
|
|
|
www.avenview.com | 7 |
|
|