16SwitchView MP Installer/User Guide
Scanning PCs
The scanning feature allows you to automatically monitor, or scan, each PC in your SwitchView system. If you use the keyboard during scanning, the scan will pause until you finish, then resume with the next PC. The length of time each PC’s video remains on the screen, or dwell time, can be changed at any time. Scanning will be halted if the Halt command is entered or if another PC is selected.
The following tables list scanning, mouse and keyboard key sequences configure.
SCANNING CONFIGURE AND CONTROL KEY SEQUENCESKey Sequence | Action |
<CTRL> <CTRL>Dnn<Enter> | Configures the dwell time. Substitute nn with a |
| value from 2 to 60 seconds. The default value is |
| 5 seconds. |
|
|
<CTRL> <CTRL>SG<Enter> | Enables the scan Go command. |
|
|
<CTRL> <CTRL>SH<Enter> | Enables the scan Halt command. |
| |
| |
SCANNING SUSPENSION KEY SEQUENCES | |
Key Sequence | Action |
|
|
<CTRL> <CTRL>M+<Enter> | Mouse will suspend scanning. |
|
|
<CTRL> | Mouse will not suspend scanning. (default) |
|
|
|
|
| EXAMPLE |
Key Sequence | Action |
1. <CTRL> <CTRL> D10<Enter> | Each PC’s video will remain on the screen for 10 |
| seconds before the next channel is displayed. |
|
|
2. <CTRL> <CTRL> SG<Enter> | Scanning begins with the current computer, then |
| continues to the next PC in sequence. |
|
|
3. <CTRL> <CTRL> SH<Enter> | Scanning is halted until the Go command is |
| issued again. |
|
|
|
|