Unit connectors

Network connector - RJ-45 Ethernet connector. Supports Power over Ethernet. Using shielded cables is recommended.

Power connector - Mini DC connector. 7-20V DC, max 5W. See product label for ± connection.

Audio in - 3.5mm input for a mono microphone, or a line-in mono signal (left channel is used from a stereo signal).

Audio out - Audio output (line level) that can be connected to a public address (PA) system or an active speaker with a built-in amplifier. A pair of headphones can also be attached. A stereo connector must be used for the audio out.

I/O terminal connector - Used in applications for e.g. motion detection, event triggering, time lapse recording and alarm notifications. It provides the interface to:

1 transistor output - For connecting exter- nal devices such as relays and LEDs. Con- nected devices can be activated by AXIS VAPIX AP, output buttons on the Live View page or by an Event Type. The out- put will show as active (shown under Event Configuration > Port Status) if the alarm device is activated.

Pin 4

Pin 2

Pin 3

Pin 1

Terminal connector. Note that the pins are numbered 1-4, right to left.

1 digital input - An alarm input for connecting devices that can toggle between an open and closed circuit, for example: PIRs, door/window contacts, glass break detectors, etc. When a signal is received the state changes and the input becomes active (shown under Event Configuration > Port Status).

Auxiliary power and GND

Function

Pin number

Notes

Specifications

 

 

 

 

GND

1

 

 

 

 

 

 

5V DC Power

2

Can be used as an alternative power supply

Max load = 100mA

 

 

(7-20VDC) or to power auxiliary equipment

 

 

 

+5VDC (100mA).

 

 

 

 

 

Digital Input

3

Connect to GND to activate, or leave float-

Must not be exposed to

 

 

ing (or unconnected) to deactivate.

voltages greater than

 

 

 

20VDC

 

 

 

 

Transistor

4

Connects to GND when activated. If used

Max load =100mA

Output

 

with an external relay, a diode must be con-

Max voltage = 24VDC

 

 

nected in parallel with the load for protec-

(to the transistor)

 

 

tion against voltage transients.

 

 

 

 

 

Page 12