Kenmore 795-71022.010 Specifications, Disconnect Power Cord Before Servicing, Important Notice

Models: 795-71022.010

1 82
Download 82 pages 6.7 Kb
Page 3
Image 3
1. SPECIFICATIONS

1. SPECIFICATIONS

1-1 DISCONNECT POWER CORD BEFORE SERVICING

IMPORTANT - RECONNECT ALL GROUNDING DEVICES

All parts of this appliance capable of conducting electrical current are grounded. If grounding wires, screws, straps, clips, nuts or washers used to complete a path to ground are removed for service, they must be returned to their original position and properly fastened.

1-2 IMPORTANT NOTICE

This information is intended for use by individuals possessing adequate backgrounds of electrical, electronic and mechanical experience. Any attempt to repair a major appliance may result in personal injury and property damage. The manufacturer or seller cannot be responsible for the interpretation of this information, nor can it assume any liability in connection with its use.

1-3 ELECTRICAL SPECIFICATIONS

Temperature Control (Freezer Compartment) .. -6°F to +8°F Defrost Control .....Total Comp Running Time: 7 hrs~50 hrs

Defrost Thermostat

46°F

Electrical Rating : 115VAC, 60Hz

5.2 A

Maximum Current Leakage

0.5 mA

Maximum Ground Path Resistance

0.14 Ohms

Energy Consumption

25 cu.ft. 547 (E/STAR)

1-4 NO LOAD PERFORMANCE CONTROL POSITION : MID/MID

And Ambient of :

70°F

90°F

Fresh Food, °F

33°F to 41°F

33°F to 41°F

Frozen Food, °F

-4°F to +4°F

-4°F to +4°F

Percent Running Time

35%-45%

50°F-70°F

1-5 REFRIGERATION SYSTEM

Minimum Compressor Capacity Vacuum

................ 21 MIN.

Minimum Equalized Pressure

 

@ 70°F

49 PSIG

@ 90°F

56 PSIG

Refrigerant R134a

4.94 oz.

Compressor

956 BTU/hr

1-6 INSTALLATION

Clearance must be provided at top, sides and rear of the refrigerator for air circulation.

AT REAR

2 in

1-7 REPLACEMENT PARTS

 

25 cuft

 

795.71022.010

 

795.71023.010

 

795.71024.010

 

795.71026.010

 

795.71029.010

Defrost Thermostat

6615JB2005H

Defrost Heater

5300JK1005D

Evaporator Fan Motor

4681JB1027C

 

(4681JK1004E)

Capacitor (Running)

EAE58905701

Compressor (Hi-Side)

TCA34649901

Evaporator (Lo-Side)

5421JJ1003B

Condenser

ACG72915205

Dryer

5851JA2007E

Condenser Fan Motor

4681JB1029D

Temperature Control

ACQ36820516(SW)

 

ACQ36820517(STS)

 

ACQ36820518(TI)

 

ACQ36820519(WB)

 

ACQ36820520(BI)

Main Control

EBR67348003

Ice Fan Motor

4681JB1027E

1-8 AIR FLOW / CIRCULATION D’AIR

- 3 -

Page 3
Image 3
Kenmore 795-71022.010 Specifications, Disconnect Power Cord Before Servicing, Important - Reconnect All Grounding Devices