8-4 Defrost Sensor Error (F dS)
No | Checking flow | Result & SVC Action |
|
|
|
1 | Check for a loose connection. |
|
2 | Check the Orange to Orange. |
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
| Result | SVC Action | ||
|
|
|
|
|
|
|
| 0 | Short | Change the sensor | ||
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| Infinite | Open | Replace the | ||
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
| ohms | refrigerator | |||
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| See |
| Check the Temp and | |
|
|
|
|
|
|
|
| resistance | Normal | |||
|
|
|
|
|
|
|
| resistance | ||||
| Check the Brown to Brown. | table |
| |||||||||
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| <Temperature | |||
|
|
|
|
|
|
|
|
| (1) To (2) | Result |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 40 |
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 30 |
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| <CON4> |
| 23 |
| ||||
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
| |||
|
| 5°F / | 17 |
| ||||||||
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 14°F / | 13 |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 23°F / | 10 |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 32°F / 0°C | 8 |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| The sensor is determined by | ||||
|
|
|
|
|
|
|
| the temperature. |
|
| ||
|
|
|
|
|
|
|
| For example, 23 | indicates |
- 28 -