4-2-3 Compressor protection logic

4-2-3 Compressor protection logic

4-2-4 Compressor problems diagnosis Since linear Comp conducts linear reciprocating motion, we have protection logic for compressor, motor and PCB as the below.

-Stroke Trip

During the operation, if stroke is above the target value, decrease the target volt by 3V.

-Current Trip

Current trip is set in order to protect compressor mechanical part and drive from the overcurrent that might arise during the operation.

Check the current for every 416.7us and if the Trip exceeds 1.86Arms more than three times at Comp ON, forcibly stop and restart six minutes later.

-Lock Piston Trip

If stroke is under 5mm even if the current is more than 14Arms, Take it as ‘piston lock’ and restart after 2’30” of Comp OFF. Check the current and stroke for every 416.7us and if the condition fits more than three times at Comp ON, the Trip occurs.

-IPM fault Trip

It occurs if FO signal received from IPM is LOW. For every 416.7us, check whether FO signal is LOW. The trip occurs if it is found three times during the five periods(83ms).

4-2-4 Compressor problems diagnosis

1) Check to normality by measurement of resistance When there is a problem or failure with the `operation, you are kindly recommended to check it as follows ;

1) Check to normality by measurement of resistance

Measure the resistance between poles of the hermetic terminal (as shown picture) with a multi-tester. (measurement several minutes after power off)

P : Power Line

 

C : Common Line

Multi-tester

 

Case 1-1

If the measured values lie in the normal resistance range as in the table below,

P : Power Line Compressor is normal.

Case 1-2

If the measured values are above several MC : Common Line or a infinity, Manual background Wire is disconnected in the shell.

Case 1-3

If the measured values are excessively of small number, Manual background There is short somewhere in the shell.

Manual background Normal resistance range (measured at ambient temperature 23Manual background)

Resistance

FC75LANE

6~8

Manual background According to ambient temperature or operation situation, the values could show a little deviation.

- 19 -