4-2-3 Compressor protection logic
Since linear Comp conducts linear reciprocating motion, we have protection logic for compressor, motor and PCB as the below.
-Stroke Trip
During the operation, if stroke is above the target value, decrease the target volt by 3V.
-Current Trip
Current trip is set in order to protect compressor mechanical part and drive from the overcurrent that might arise during the operation.
Check the current for every 416.7us and if the Trip exceeds 1.86Arms more than three times at Comp ON, forcibly stop and restart six minutes later.
-Lock Piston Trip
If stroke is under 5mm even if the current is more than 14Arms, Take it as ‘piston lock’ and restart after 2’30” of Comp OFF. Check the current and stroke for every 416.7us and if the condition fits more than three times at Comp ON, the Trip occurs.
-IPM fault Trip
It occurs if FO signal received from IPM is LOW. For every 416.7us, check whether FO signal is LOW. The trip occurs if it is found three times during the five periods(83ms).
4-2-4 Compressor problems diagnosis
When there is a problem or failure with the `operation, you are kindly recommended to check it as follows ;
1) Check to normality by measurement of resistance
Measure the resistance between poles of the hermetic terminal (as shown picture) with a
P : Power Line |
|
C : Common Line | |
|
Case
If the measured values lie in the normal resistance range as in the table below,
Compressor is normal.
Case
If the measured values are above several M or a infinity, Wire is disconnected in the shell.
Case
If the measured values are excessively of small number, There is short somewhere in the shell.
Normal resistance range (measured at ambient temperature 23)
Resistance
FC75LANE | 6~8 |
According to ambient temperature or operation situation, the values could show a little deviation.