No | Checking flow | Result & SVC Action |
1Reset the unit and Input Test 1 Mode. (Push the button 1 time)
2 | Open the refrigerator door and Check the |
|
|
| Status | SVC Action |
|
| air flow. |
|
|
|
| ||
|
|
|
|
|
|
| |
|
|
|
| No airflow | Go to the 3,4 |
| |
| While an error code is displayed, |
|
|
|
| ||
| the fan is not working. |
|
|
|
|
|
|
|
|
|
| Airflow | Go to the 5 |
| |
|
|
|
|
| |||
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3 | Check the Connector. | Tip |
|
| |||
| (Frozen caused the PCB short) | To protect ice short, add wire seal in | |||||
|
| connector. We developed new type | |||||
|
| connector, so order the new type. |
4Check the Fan motor. (Frozen, Lock, ect.)
Wire seal (Silicon)
No | Part Name | Old P/No | New P/No | |
407A | Duct Asm, | 5209JA | 5209JA | |
Connector | 1044A | 1044A | ||
| ||||
|
|
|
|
5Check the Fan motor voltage.
(2) |
| Result |
| SVC Action | ||
|
|
|
|
|
|
|
|
|
| (1) ~ (2) | Below 9 | V | Change the PCB |
|
|
|
|
|
|
|
|
|
| (2) ~ (3) | 0 or 5 V | Change the motor | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
(1) (3)
<CON4>
- 31 -