Kenmore 795-71022.010 service manual Duct Asm

Models: 795-71022.010

1 82
Download 82 pages 6.7 Kb
Page 31
Image 31
Duct Asm,

8-7 Icing Fan Error (Er IF)

No

Checking flow

Result & SVC Action

1Reset the unit and Input Test 1 Mode. (Push the button 1 time)

2

Open the refrigerator door and Check the

 

 

 

Status

SVC Action

 

 

air flow.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No airflow

Go to the 3,4

 

 

While an error code is displayed,

 

 

 

 

 

the fan is not working.

 

 

 

 

 

 

 

 

 

 

Airflow

Go to the 5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

Check the Connector.

Tip

 

 

 

(Frozen caused the PCB short)

To protect ice short, add wire seal in

 

 

connector. We developed new type

 

 

connector, so order the new type.

4Check the Fan motor. (Frozen, Lock, ect.)

Wire seal (Silicon)

No

Part Name

Old P/No

New P/No

407A

Duct Asm,

5209JA

5209JA

Connector

1044A

1044A

 

 

 

 

 

5Check the Fan motor voltage.

(2)

 

Result

 

SVC Action

 

 

 

 

 

 

 

 

 

 

(1) ~ (2)

Below 9

V

Change the PCB

 

 

 

 

 

 

 

 

 

 

(2) ~ (3)

0 or 5 V

Change the motor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(1) (3)

<CON4>

- 31 -

Page 31
Image 31
Kenmore 795-71022.010 service manual Duct Asm