9. Troubleshooting Without Error Display

9. Troubleshooting Without Error Display

9-1 Cube mode doesn’t work

No

 

 

Checking flow

 

 

 

Result & SVC Action

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

Check the loose connection.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

Check the Black to Blue.

 

 

 

 

 

 

 

 

Lever s/w

Result

 

SVC Action

 

 

(While pushing the lever S/W)

 

 

 

 

 

Activated

112 ~ 115 V

 

Go to the 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Other

 

Change PCB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Not

0 ~ 2 V

 

Go to the 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

activated

 

 

 

 

 

 

 

 

 

 

 

 

Other

 

Change PCB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<CON2>

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

Check the Red to Blue.

 

 

 

 

 

 

 

 

Lever s/w

Result

 

SVC Action

 

 

(While pushing the lever S/W)

 

 

 

 

 

Activated

9 ~ 12 V

 

Go to the 4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Other

 

Change PCB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Not

0 ~ 2 V

 

Go to the 4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

activated

 

 

 

 

 

 

 

 

 

 

 

 

Other

 

Change PCB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<CON2>

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

Check the resistance value.

 

 

 

 

 

 

 

 

Point

 

Result

 

SVC Action

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(1) to (2)

 

31.1 ~ 42.1

 

Normal

 

 

 

 

 

 

 

 

 

 

Other

 

Replace

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Geared Motor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9.9 ~ 12.1

 

Normal

 

 

 

 

 

 

 

 

 

(3) to (4)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Other

 

Replace

 

 

 

 

 

 

 

 

 

 

 

 

Geared Motor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<Ice Maker>

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(1)

(2)

 

(3)

 

 

 

 

 

 

 

 

(4)

 

<Geared Motor>