![Below 12 V](/images/new-backgrounds/84020/8402059x1.webp)
No | Checking flow | Result & SVC Action |
1Reset the unit and Input Test 1 Mode. (Push the button 1 time)
2 | Open the freezer door and Check the air |
|
|
| Status | SVC Action |
|
| flow. |
|
|
|
| ||
|
|
|
| No airflow | Go to 3 |
| |
| While an error code is displayed, |
|
|
|
| ||
| the fan is not working. |
|
|
|
|
|
|
|
|
|
| Airflow | Go to 4 |
| |
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3 | Check the Fan motor. | Rotate fan using your hand. |
|
| |||
|
|
|
| ||||
|
| It feel stuck or locked up, change the motor. | |||||
|
| (Cause of ice or rust inside of motor) |
4Check the Fan motor voltage.
(2) | Point | Result | SVC Action | |
|
| (1) ~ (2) | Below 12 V | Change the PCB |
|
| |||
|
|
|
|
|
|
| (2) ~ (3) | 0 or 5 V | Change the motor |
|
|
|
|
|
(1) (3)
<CON4>
- 30 -