6. TROUBLESHOOTING

6. TROUBLESHOOTING

ERROR CODE on display panel

 

Error Detection

Error Display

 

 

NO

 

 

Error Generation Factors

Remark

Freezer

Ref.

Category

 

Temperature

Temperature

 

 

 

 

 

 

 

 

 

 

 

 

1

Normality

 

 

None

Normal operation of Display

 

 

 

 

 

 

2

Freezer Sensor

Er

FS

Short or Disconnection of

 

Error

Freezer Sensor

 

 

 

 

 

 

 

 

 

 

 

3

Refrigerator

Er

rS

Short or Disconnection of

 

Sensor Error

Refrigerator Sensor

Each Sensor have to check

 

 

 

 

 

 

 

 

 

 

 

 

 

disconnection

4

Defrosting Sensor

Er

dS

Short or Disconnection of

 

Error

Defrosting Sensor

 

 

 

 

 

 

 

 

 

 

 

5

Icing Sensor Error

Er

IS

Short or Disconnection of

 

Icing Sensor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Even though it is passed

Temperature Fuse

6

Poor Defrosting

Er

dH

1hour since then Defrosting,

Disconnection, Heater

if Defrosting sensor is not

disconnection, DRAIN Jam,

 

 

 

 

 

 

 

 

over 46°F(8°C), it is caused

Poor Relay for Heater

 

 

 

 

 

 

 

Abnormality of

 

 

It is caused when F/B signal

Poor BLDC Motor connection,

7

Brushless DC

Er

IF

isn’t over 65 seconds during

DRIVE IC, and TR

FAN Motor for Ice

Brushless DC FAN motor

 

 

 

 

 

 

Making

 

 

operating

 

 

 

 

 

 

 

 

Abnormality of

 

 

It is caused when F/B signal

Poor BLDC Motor connection,

8

Brushless DC

Er

FF

isn’t over 65seconds during

DRIVE IC, and TR

FAN Motor for

Brushless DC FAN motor

 

 

Freezer

 

 

operating

 

 

 

 

 

 

 

 

Abnormality of

 

 

It is caused when F/B signal

Poor BLDC Motor connection,

9

Brushless DC

Er

CF

isn’t over 65seconds during

DRIVE IC, and TR

FAN Motor for

Brushless DC FAN motor

 

 

 

 

 

 

Mechanic Room

 

 

operating

 

 

 

 

 

 

 

 

Communication

 

 

Communication Error

Poor Communication

10

Er

CO

between Micom of Main PCB

connection, Poor TR of

Error

 

 

 

and Display Micom

Transmitter and Receiver

 

 

 

 

 

 

 

 

 

 

NOTE) In the case of Room Temperature Seneor Error, “Er rt” appears on the Display when Ultra Ice KEY and Freezer Temp’ KEY pressed at the same time for one second.