6. TROUBLESHOOTING
ERROR CODE on display panel
| Error Detection | Error Display |
|
| ||
NO |
|
| Error Generation Factors | Remark | ||
Freezer | Ref. | |||||
Category | ||||||
| Temperature | Temperature |
|
| ||
|
|
|
| |||
|
|
|
|
|
| |
1 | Normality |
|
| None | Normal operation of Display | |
|
|
|
|
|
| |
2 | Freezer Sensor | Er | FS | Short or Disconnection of |
| |
Error | Freezer Sensor |
| ||||
|
|
|
| |||
|
|
|
|
|
| |
3 | Refrigerator | Er | rS | Short or Disconnection of |
| |
Sensor Error | Refrigerator Sensor | Each Sensor have to check | ||||
|
|
| ||||
|
|
|
|
| ||
|
|
|
|
| disconnection | |
4 | Defrosting Sensor | Er | dS | Short or Disconnection of | ||
| ||||||
Error | Defrosting Sensor |
| ||||
|
|
|
| |||
|
|
|
|
|
| |
5 | Icing Sensor Error | Er | IS | Short or Disconnection of |
| |
Icing Sensor |
| |||||
|
|
|
|
| ||
|
|
|
|
|
| |
|
|
|
| Even though it is passed | Temperature Fuse | |
6 | Poor Defrosting | Er | dH | 1hour since then Defrosting, | Disconnection, Heater | |
if Defrosting sensor is not | disconnection, DRAIN Jam, | |||||
|
|
|
| |||
|
|
|
| over 46°F(8°C), it is caused | Poor Relay for Heater | |
|
|
|
|
|
| |
| Abnormality of |
|
| It is caused when F/B signal | Poor BLDC Motor connection, | |
7 | Brushless DC | Er | IF | isn’t over 65 seconds during | DRIVE IC, and TR | |
FAN Motor for Ice | Brushless DC FAN motor |
| ||||
|
|
|
| |||
| Making |
|
| operating |
| |
|
|
|
|
|
| |
| Abnormality of |
|
| It is caused when F/B signal | Poor BLDC Motor connection, | |
8 | Brushless DC | Er | FF | isn’t over 65seconds during | DRIVE IC, and TR | |
FAN Motor for | Brushless DC FAN motor |
| ||||
| Freezer |
|
| operating |
| |
|
|
|
|
|
| |
| Abnormality of |
|
| It is caused when F/B signal | Poor BLDC Motor connection, | |
9 | Brushless DC | Er | CF | isn’t over 65seconds during | DRIVE IC, and TR | |
FAN Motor for | Brushless DC FAN motor |
| ||||
|
|
|
| |||
| Mechanic Room |
|
| operating |
| |
|
|
|
|
|
| |
| Communication |
|
| Communication Error | Poor Communication | |
10 | Er | CO | between Micom of Main PCB | connection, Poor TR of | ||
Error | ||||||
|
|
| and Display Micom | Transmitter and Receiver | ||
|
|
|
| |||
|
|
|
|
|
|
NOTE) In the case of Room Temperature Seneor Error, “Er rt” appears on the Display when Ultra Ice KEY and Freezer Temp’ KEY pressed at the same time for one second.
- 22 -