8-5 Defrost Heater Error (Er dH)
No | Checking flow |
|
|
| Result & SVC Action | |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
1 | Check the Door gasket. |
|
|
|
|
|
| |||||
|
| Part | Result | SVC Action |
| |||||||
|
|
|
|
|
|
|
|
| 0 | Go to the 3 |
| |
2 | Check the Defrost control part. |
|
| |||||||||
|
|
|
|
| ||||||||
|
|
| Change |
| ||||||||
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Defrost | 34~42 | Go to the 3 |
|
| Fuse |
|
|
| Defrost |
| Heater |
| Change |
| ||
|
|
| ||||||||||
| M |
|
|
| Sensor |
|
|
|
|
| ||
|
|
|
|
|
|
| 0 | Go to the 3 |
| |||
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Check the resistance of |
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
| the defrost sensor wires |
|
| Defrost Heater |
|
| Defrost | Infinite | back to the main PCB. |
| |||||
|
|
|
|
|
|
|
|
| Sensor | If they are open |
| |
|
|
|
|
|
|
|
|
|
| ohms | between the Main PCB |
|
|
|
|
|
|
|
|
|
|
|
| and the connector for |
|
|
|
|
|
|
|
|
|
|
|
| the icemaker it will be |
|
|
|
|
|
|
|
|
|
|
|
| necessary to replace |
|
|
|
|
|
|
|
|
|
|
|
| the refrigerator. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3Input Test 3 Mode. (Push the button 3 times)
4Check the Blue to Orange.
Result | SVC Action |
|
|
112 ~ 116 V | Go to the 5 |
|
|
0 V | Replace Main PCB |
|
|
<CON3>
5Release the test mode.
Push the button 1 times. (Normal)
6Check the Blue to Orange.
Result | SVC Action |
0 V | Normal |
|
|
112 ~ 116 V | Replace Main PCB |
|
|
<CON3>
- 29 -