8-2 Refrigerator Sensor Error (Er rS)
No |
| Checking flow |
|
|
| Result & SVC Action |
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
1 | Check for a loose connection. |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
2 | Check the White to White. |
|
|
|
|
|
|
|
| ||
| Result | SVC Action |
| ||||||||
|
|
|
|
|
|
| |||||
|
|
|
|
| 0 |
| Short | Change the sensor |
| ||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
| Infinite |
| Open | Replace the |
| ||
|
|
|
|
|
|
| |||||
|
|
|
|
| ohms |
| refrigerator |
| |||
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| See |
|
| Check the Temp and |
| |
|
|
|
|
| resistance |
| Normal |
| |||
|
|
|
|
|
|
| |||||
|
|
|
|
|
| resistance |
| ||||
|
|
|
|
| table |
|
|
| |||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| <CON4> |
|
| <Temperature |
| ||||
|
|
|
|
|
|
|
|
|
|
| |
|
|
| (1) To (2) | Result |
|
| |||||
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| 23°F / | 38 |
|
| ||
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| 32°F / 0°C | 30 |
|
| ||
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| 41°F / 5°C | 24 |
|
| ||
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| 50°F / 10°C | 19.5 |
|
| ||
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| 59°F / 15°C | 16 |
|
| ||
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
| The sensor is determined by |
| |||||
|
|
|
|
| the temperature. |
|
|
| |||
|
|
|
|
| For example, 30 | indicates 32°F. |
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
- 26 -