Actions to take according to Led blinking frequency

Actions to take according to Led blinking frequency

No

 

LED operating condition

 

Cause

 

Service guideline

 

 

 

 

 

 

 

 

 

 

 

 

1.

Please check, Whether

 

 

 

 

PCB Parts

 

connector of

 

 

 

 

 

compressor is attached

 

 

 

 

defect or

 

 

LED two - time

repetiton (Stroke Trip)

 

 

rightly or not. after

 

 

Compress

 

 

 

 

power off

 

 

 

 

or

 

1

 

 

 

2.

After the first action,

 

 

 

Connector

 

 

 

 

miss

 

You check on normal

 

on - on - off - on - on - off - on - on - off repeating

 

 

operation of

 

 

connecting

 

 

 

 

 

(Piston

 

compressor.

 

 

 

 

3.

If the same symptom

 

 

 

 

over run)

 

 

 

 

 

arises after the second

 

 

 

 

 

 

 

 

 

 

 

 

action, replace PCB

 

 

 

 

 

 

 

 

 

 

 

 

1.

After resetting power,

 

 

 

 

 

 

check if it is running

 

LED four - time

repetiton (Overload Protect)

 

 

 

normal

 

 

 

2.

If the same symptom

 

 

 

 

Outlet

2

 

 

 

 

arises after the first

 

 

 

clogging

 

action

 

 

 

 

 

 

on - on - on - on - off - on - on - on - on - off repeating

 

 

3.

If the same symptom

 

 

 

 

arises after the second

 

 

 

 

 

 

 

 

 

 

 

 

action, replace

 

 

 

 

 

 

compressor

 

 

 

 

 

 

 

 

 

 

 

 

1.

After resetting power,

 

 

 

 

 

 

check if it is running

 

LED five - time

repetiton (Piston Lock Trip)

 

 

 

normal

 

 

 

2.

If the same symptom

 

 

 

 

 

3

 

 

 

Piston

 

arises after the first

 

 

 

constraint

 

action

 

 

 

 

 

 

on - on - on - on - on - off - on - on - on - on - on - off repeating

 

3.

If the same symptom

 

 

 

arises after the second

 

 

 

 

 

 

 

 

 

 

 

 

action, replace

 

 

 

 

 

 

compressor

 

 

 

 

 

 

 

 

 

 

 

 

1.

After resetting power,

 

 

 

 

 

 

check if it is running

 

LED six - time

repetiton (Current Trip)

 

Circuit

 

normal

 

 

over

2.

If the same symptom

 

 

 

 

4

 

 

 

current

 

arises after the first

 

 

 

error

 

action

 

 

 

 

 

 

on - on - on - on - on - on - off - on - on - on - on - on - on - off

repeating

Or cycle

3.

If the same symptom

 

 

 

 

error

 

arises after the second

 

 

 

 

 

 

action, replace

 

 

 

 

 

 

compressor

 

 

 

 

 

 

 

 

LED seven- time repetiton (IPM Fault Trip)

 

 

1.

After resetting power,

 

 

PCB parts

 

check if it is running

 

 

 

 

 

 

 

 

 

 

normal

5

 

 

 

defect

 

 

 

 

2.

If the same symptom

 

 

 

 

(IPM)

 

on - on - on - on - on - on - on - off - on - on -on - on - on - on- on - off

repeating

 

arises after the first

 

 

 

 

 

 

action, replace PCB

 

 

 

 

 

 

 

 

 

 

 

 

 

- 48 -