12-3-1 SEALED SYSTEM DIAGNOSIS

12-3-1 SEALED SYSTEM DIAGNOSIS

“Not Cooling” Complaint

All components operating, No airflow problems, Not frosted up as a defrost problem

problem has been isolated to sealed system area

PartialFrost

Pattern?

Equalization

Test

 

Very Fast

 

 

 

 

Very Slow

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fast

Inefficient

Partial

Compressor

Restriction

Condenser

Temperature

Hotter than Normal

Room Temperature

Air/Low Side

Leak

Trace of Oil

Yes

None

Equalization

Test

Very Slow

Very Fast

Complete

Restriction

Cap Tube

Sound

Faint

None to Weak

Loss of Change

Compressor Not

Pumping

No

Leak

Undercharge

(The equalization test is trying to restart a compressor using a start kit after it has been operating.)