Insulation check : Check for infinite Ohms between all compressor terminal and ground.
FC90LANA
Capacitor Spec. 450V/18uF 5%
Po N/C
Co
Po : Power
Co : Common
N/C : No Connecting
Compressor Winding Resistance Check
6 ~ 8 Ω Between Po and Co
FC75LANE
Capacitor Spec. 550V/10uF 5%
Po N/C
Co
Po : Power
Co : Common
N/C : No Connecting
Compressor Winding Resistance Check
6 ~ 8 Ω Between Po and Co
LG Linear Compressor
NOTE : Any Terminal to Ground should read Inf ( ~ )
| Inf (~) |
6 ~ 8 Ω | 6 ~ 8 Ω Inf (~) |
- 61 -