11. COMPONENT TESTING INFORMATION

11. COMPONENT TESTING INFORMATION

11-1 Defrost Controller Assembly

Function

- Controller assembly is consist of 2 kinds of part those are fuse-m and sensor. we can

 

decide part is defect or not when we check the resistance.

 

- Fuse-M can cut off the source when defrost heater operate the unusual high temperature.

 

- Sensor give temperature information to Micom

 

 

 

How to

 

Measure the 2 pin connected to Fuse-M.

Measure

 

 

If the ohmmeter indicate below 0.1ohm

(Fuse-M)

 

 

Fuse-M is good. If Fuse-M measures infinite

 

 

 

(1) to (2)

ohms, it is open and needs to be replaced.

How to Measure (Sensor)

 

Measure the 2 pin connected to Sensor.

 

If the ohmmeter indicate 11 (at room

 

temperature) It is normal.

 

Checking the resistance at other

(1) to (2)

temperatures, check the sensor resistance

chart.

Standard

Fuse-M (at all temperature)

Test Point

Ressult

(1) to (2)

0 ~ 0.1

 

 

Sensor (at room temperature)

Test Point

Ressult

(1) to (2)

11

 

 

- 49 -