Shindaiwa SP518 Optional Accessories, Maintenance, Available Spray Nozzles, Cleaning the Sprayer

Models: 80702 SP518

1 6
Download 6 pages 50.18 Kb
Page 6
Image 6
Optional Accessories

Optional Accessories

Part Number Description

Part Number Description

Maintenance

Cleaning the Sprayer

Pump Disassembly (cont.)

761882 Spray hood is used for nonselec- tive herbicides when spraying under windy conditions. Comes with Kematal 110-DEF-06 deflector fan nozzle and parts to assemble spray hood to your existing Shindaiwa spray wand.

902296 Brass spray boom (27.5") for use with agrochemicals and foliar fertilizers applied to row crops. Provides 40" coverage. JD-12P cone nozzles and 40 mesh stainless steel filter included.

907873 Flexible annealed copper boom fitted with three JD-12P cone nozzles. For use with agrochemicals and foliar fertilizers on row crops. Can be easily shaped as appropriate to provide proper coverage.

40 mesh stainless steel filter included.

831107 Brass extension (11.8") complete with plastic fittings for extra reach. Attach- able to original wand .

728139 Brass extension (23.6") complete

838052 Constant pressure valve reduces pumping action, reduces drift and delivers uniform spraying. Improves productivity and saves chemicals.

565648 Plastic anti-drip valve for agrochemicals and foliar fertilizer applica- tion. Attaches to wand and is compatible with any type of cone or flat fan nozzle.

568774 Spray wand assembly (21.6") Plastic handle, trigger valve and spray tube. 40 mesh stainless steel nozzle and trigger valve filters included. Fitted with adjustable cone nozzle.

725267 All brass spray wand assembly

(21.6") for extra duty applications. Trigger valve and spray tube are brass. 40 mesh stainless steel nozzle and trigger valve filters included. Fitted with JD-12P cone nozzle.

After finishing the spray application, empty the sprayer and wash all equipment in an approved decontamination area.

Pump the lever with

the trigger valve

disconnected until the discharge runs clear

WARNING!

2.Using the 452284 all-purpose wrench, remove the chamber valve and cups. Replace as necessary.

3.Remove the two flanged nuts from the outside of the tank below the pump cylinder with a 10 mm socket and remove the cylinder.

4.Remove the two Phillips head screws located at the bottom of the cylinder and remove the cylinder base.

5.From the bottom of the cylinder, push the ball seat assembly towards the top and out of the cylinder.

6.Unscrew the ball lock from the valve seat and remove the ball and seat.

7.Clean all parts and carefully inspect for worn or damaged parts and replace as necessary.

8.Reassemble in the reverse order.

Pump

Chamber

Piston

Cup

Spacer

Piston

Cup

Chamber

Valve

Ball Lock

Ball

Seat Maintenance

Valve Seat

O-Ring Cleaning the Sprayer

Cylinder

with plastic fittings for extra reach. Attach- able to original wand .

100016 Brass extension (6.3") complete with two JD-12P cone nozzles for doubling output of agrochemicals and foliar fertilizers on perennials. 40 mesh stainless steel filter included.

646901 Flow calibrator bottle. For accurate calibration of backpack sprayers to prevent waste and damage to the environ- ment.

336115 Brass Y nozzle for use on plants requiring heavy applications of fungicides. Complete with two JD-12P cone nozzles, 40 mesh stainless steel filter and plastic fittings.

285221 Standard Repair Kit and Nozzle for SP518. Includes (2) Piston cups, trigger valve needle, nozzle filter, JD-12P cone nozzle, nozzle cap, and deflector nozzle.

229724* Nozzle cap for attaching flat fan and cone type nozzles.

452284 All Purpose Wrench for periodic maintenance and repair.

Remove all chemicals and wash before storing the sprayer. Chemical products have different reactions and can cause damage to the sprayer components and the environment. Unidentified chemicals left in the sprayer tank can pose a serious health threat to anyone servicing the unit and unaware of its presence!

Lubricate

Lubricate

(disassembly

 

Bolt

NOTE:

 

Lubricating all moving parts with a high

Cylinder

quality lithium grease will ease assembly

Base

 

 

and prolong the life of the unit.

Screw

Troubleshooting: Lack of Pressure

Flanged

Nut

 

 

 

 

 

 

SYMPTOM

 

CAUSE
REMEDY

Leakage through

Worn or dried out

Lubricate or replace

the upper cylinder.

piston cups.

the piston cups.

After pumping and

Cylinder ball or seat

Clean or replace the

pressurizing the

not sealing properly

cylinder ball or seat.

chamber, the pump

due to wear or

 

 

lever drops rapidly

impurities.

 

 

AVAILABLE SPRAY NOZZLES

Nozzle Type

Part Number
Application
Pressure
Flow Rate

psi (kg/cm2)

gal (ml)/min

Flat Fan

437756

110-SF-015 Kematal green, 0.16 gpm @ 45 psi

 

45 (3.2)

0.16 (610)

 

437764

110-SF-02 Kematal yellow, 0.21 gpm @ 45 psi

Herbicides

45 (3.2)

0.21 (810)

 

437772

110-SF-03 Kematal blue, 0.33 gpm @ 45 psi

 

45 (3.2)

0.33 (1250)

Cone

717942

JD-10A Stainless steel

 

45 (3.2)

0.08 (300)

 

 

 

 

217174*

JD-12P Stainless steel

 

45 (3.2)

0.16 (615)

Flat Fan

437855

110-LD-03 Kemetal blue, 0.33 gpm @ 45 psi

 

 

45 (3.2)

0.16 (615)

Low Drift

 

 

 

 

 

 

 

 

required)

Lubricate

Periodically clean and lubricate the pump chamber and actuating linkage with a high quality lithium grease.

Pump Disassembly

when released.

 

 

After pumping and

Chamber valve not

Clean or replace the

pressurizing the

sealing properly

chamber valve.

chamber, the pump

due to wear or

 

lever rises slowly

impurities.

 

when released.

 

 

Low pressure and

Pump chamber

Tighten screw cap

pump lever hard to

filled with liquid.

at top of chamber.

operate.

 

With an empty tank,

 

 

pump lever with

 

 

trigger valve open

 

 

until all liquid is

 

 

 

 

 

 

 

45 (3.2)

0.22 (830)

 

 

Cone

457317

HC-02 Kematal yellow

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Agrochemicals

45 (3.2)

0.44 (1680)

 

 

 

457325

HC-04 Kematal red

 

 

 

 

 

 

 

 

and foliar

 

 

 

 

 

 

457333

HC-05 Kematal brown

 

15 (1.0)

0.54 (2060)

 

 

 

 

fertilizers

 

 

 

 

 

 

 

 

 

 

 

 

Flat fan

457390

DEF-04 Kematal red

 

 

15 (1.0)

0.25 (950)

 

 

 

 

 

 

 

 

 

 

 

 

Deflector 457408

DEF-05 Kematal brown

 

 

15 (1.0)

0.32 (1200)

 

 

 

457416*

DEF-06 Kematal gray

 

 

 

 

 

 

 

 

 

 

45 (3.2)

0.41 (1540)

 

 

 

 

 

 

 

 

 

 

Adjustable

323725

Yellow

0.08 gpm @ 45 psi.

 

 

45 (3.2)

0.08 (315)

 

 

Cone

015024

Red

0.17 gpm @ 45 psi.

 

 

45 (3.2)

0.17 (640)

 

 

 

 

 

 

 

 

 

 

 

325787

Blue

0.18 gpm @ 45 psi.

 

 

 

 

 

 

 

 

 

 

 

 

 

* Denotes nozzles included in the SP518

Note: All Shindaiwa sprayers come with the red adjustable

6

 

standard repair kit.

cone nozzle P/N 015024 installed as standard equipment.

 

 

 

 

 

 

 

 

 

 

1.Remove the pump lever connecting rod from the chamber. Loosen the packing ring nut that secures the chamber to the tank. Remove the tank lid and strainer, reach inside the tank and slide the agitator down the pump cham- ber, then remove the chamber from the cylinder.

Packing

Screw Cap

Ring Nut

 

Pump Lever

 

Connecting Rod

 

purged from pump.

Pump Chamber

Piston Cup

Chamber Valve

Cylinder

Pump Disassembly (cont.) Cylinder Ball

7

Page 6
Image 6
Shindaiwa SP518 Optional Accessories, Maintenance, Available Spray Nozzles, Cleaning the Sprayer, Pump Disassembly cont