AXIS P1214 Network Camera

Troubleshooting

Lower frame rate than

See Performance Considerations, on page 47.

expected

Reduce the number of applications running on the client computer.

 

 

Limit the number of simultaneous viewers.

 

Check with the network administrator that there is enough bandwidth available.

 

Check in the AMC Control Panel (H.264 tag) that video processing is NOT set to Decode only

 

key frames.

 

Lower the image resolution.

 

The maximum frames per second is dependent on the utility frequency (60/50 Hz) of the Axis

 

product. See Technical Specifications, on page 45.

Status and Network indicator LEDs are flashing red rapidly

 

 

Hardware failure

Contact your Axis reseller.

Video and image problems, general

 

 

Image unsatisfactory

Check the video stream and camera settings under Setup > Video > Video Stream and Setup >

 

Video > Camera Settings.

Motion Detection triggers unexpectedly

 

 

Changes in luminance

Motion detection is based on changes in luminance in the image. This means that if there are

 

sudden changes in the lighting, motion detection may trigger mistakenly. Lower the sensitivity

 

setting to avoid problems with luminance.

Storage and disk management problems

 

 

Video cannot be recorded

Check that the SD card is not write protected (that is, read only).

SD card cannot be mounted

Reformat the SD card and then click Mount.

44

Page 44
Image 44
Axis Communications P1214-E Key frames, Status and Network indicator LEDs are flashing red rapidly, Video Camera Settings