Shorten Sensor Unit Cable

The sensor unit is delivered with a cable. To shorten the cable follow these steps:

1.Cut the cable to the desired length. Measure from the sensor unit.

2.Strip the plastic outer coating from the end of the cable.

3.Peel back the shield.

4.Flatten the colored wires in the order described below.

1Brown

2White/brown

3Not used

4Not used

5White/blue

6Blue

NOTICE

Make sure that the wires stay in the correct order and that the cable shield makes good contact with the connector shield.

5.Insert the wires all the way into a shielded 6P6C RJ12 connector.