Page 12

AXIS P1353/P1354 Installation Guide

RS-485/422 - two 2-pin terminal blocks for RS-485/422 serial interface used to control auxiliary equipment.

The RS-485/422 serial port can be configured in the following port modes:

Bidirectional RS-485 half-duplex port for data transmission using two wires, one combined RX/TX pair.

Bidirectional RS-485 full-duplex port for data transmission using four wires, one RX pair and one TX pair.

Unidirectional RS-422 port for transmitting or receiving data using two wires, RX- or TX pair.

Bidirectional RS-422 full-duplex port for data transmission (point-to-point) using four wires, one RX pair and one TX pair.

Function

Pin

Notes

 

 

 

RS 485/422TX(A)

1

TX pair for RS-422 and 4-wire RS-485

 

 

 

RS 485/422TX(B)

2

 

 

 

 

RS-485A alt RS-485/422RX(A)

3

RX pair for all modes (combined RX/TX for 2-wire RS-485)

 

 

 

RS-485B alt RS-485/422RX(B)

4

 

 

 

 

Rx/Tx

 

4

3

 

Tx

2

1

Page 12
Image 12
Axis Communications P1353, P1354 manual Function Pin