AXIS P5532/P5534 Installation Guide | Page 21 |
•Digital input - An alarm input for connecting devices that can toggle between an open and closed circuit, for example: PIRs, door/window contacts, glass break detectors, etc. When a signal is received the state changes and the input becomes active (shown under
Events > Port Status).
Function | Pin | Notes | Specifications |
|
|
|
|
GND | 1 | Ground |
|
|
|
|
|
3.3 V DC | 2 | Can be used to power auxiliary equipment. | Max. load = 250 mA |
Power |
| Note: This pin can only be used as power out. |
|
|
|
|
|
Configurable | Digital input – Connect to GND to activate, or leave floating | Min. input = | |
(input or |
| (unconnected) to deactivate. | Max. input = +40 V DC |
Output) |
|
|
|
| Digital output – Uses an | Max. load = 100 mA | |
|
| ||
|
| source connected to GND. If used with an external relay, a | Max. voltage = +40 V DC |
|
| diode must be connected in parallel with the load, for pro- |
|
|
| tection against voltage transients. |
|
|
|
|
|
AXIS P5532/P5534 Status indicators
Color | Indication |
|
|
Unlit | Steady connection/normal operation |
|
|
Amber | Steady during system initiating and reset to factory default. Flashes during firmware upgrade. |
|
|
Amber/red | No network connection |
|
|
Red | Firmware upgrade failure |
|
|
Green | Steady for 10 sec. after successful restart |
|
|
Note:
For more information on the AXIS P5532/P5534 status indicators, please see the User’s Manual available from the AXIS Network Video Product CD supplied with this product or from the website at www.axis.com
AXIS T8123 Status indicators
LED | Color | Indication |
|
|
|
Port | Unlit | No camera connected |
|
|
|
| Flashing | Power overload or other input voltage error |
|
|
|
| Green | Camera connected, normal behavior |
|
|
|
AC input | Steady green | AC power connected |
|
|
|
ENGLISH