CHAPTER 5: SELECTING DIPSWITCH SETTINGS
The 232SPS2 is set up using an
Converter direction - Can operate as a parallel to serial converter or as a serial to parallel converter. The direction is set by dipswitch position 8.
Baud rate - Can be set from 1200 to 115.2k baud. The baud rate is determined by dipswitch positions
Flow control - Can be set for DTR control or XON/XOFF control. The type of flow control used is determined by dipswitch position 4.
Data bits - Can be set for 7 or 8 data bits. The number of data bits is determined by dipswitch position 5.
Parity - Can be enable or disabled by dipswitch position 6. If parity is enabled, dipswitch position 7 determines whether the parity is even or odd.
B&B Electronics
PH (815)
Table 5.1
Setting |
|
| DIP SWITCH POSITION |
|
| |||
| 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
1200 Baud | OFF | OFF | OFF | X | X | X | X | X |
2400 Baud | ON | OFF | OFF | X | X | X | X | X |
4800 Baud | OFF | ON | OFF | X | X | X | X | X |
9600 Baud | ON | ON | OFF | X | X | X | X | X |
19.2K Baud | OFF | OFF | ON | X | X | X | X | X |
38.4 Baud | ON | OFF | ON | X | X | X | X | X |
57.6K Baud | OFF | ON | ON | X | X | X | X | X |
115.2K Baud | ON | ON | ON | X | X | X | X | X |
XON/XOFF | X | X | X | OFF | X | X | X | X |
DTR control | X | X | X | ON | X | X | X | X |
8 Data bits | X | X | X | X | OFF | X | X | X |
7 Data bits | X | X | X | X | ON | X | X | X |
No parity | X | X | X | X | X | OFF | X | X |
Parity enable | X | X | X | X | X | ON | X | X |
Even parity | X | X | X | X | X | X | OFF | X |
Odd parity | X | X | X | X | X | X | ON | X |
Serial to Par. | X | X | X | X | X | X | X | OFF |
Par. to Serial | X | X | X | X | X | X | X | ON |
Example #1 - Parallel to Serial Mode, hardware handshaking, 9600 baud, 8 data bits, no parity
Dipswitch position settings for Example #1 ("X" = don't care)
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
ON | ON | OFF | ON | OFF | OFF | X | ON |
Example #2 - Serial to Parallel Mode, XON/XOFF flow control, 2400 baud, 7 data bits, odd parity
Dipswitch position settings for Example #2
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
ON | OFF | OFF | OFF | ON | ON | ON | OFF |
10 Chapter 5: Selecting Dipswitch Settings
B&B Electronics
PH (815)