Image 17

Example: A unit with a decimal address of ten will have a delay of 220 milliseconds [(10 x 0.02) + 0.02 = 0.22 seconds].

Command character: ACK (decimal 6)

Example 1: To request status from the 485DSS set to address 11 ( 0B hex) decimal.

HOST transmits: Xoff

“0”

“B”

ACK

( 19

48

66

6 decimal)

( 13

30

42

6 hex)

Reply: “A” “0” “B” “0” “1” cr

The reply indicates that the RS-232 port has no connection to the network on unit 11 and the CTS handshake line is in the high state.

Example 2: Request status from all the 485DSS's on the network.

HOST transmits: Xoff

DC2

DC2

ACK

( 19

18

18

6 decimal)

( 13

12

12

6 hex)

Reply: “A” “0” “1” “0” “0” cr

Reply: “A” “0” “2” “1” “0” cr

Reply: “A” “0” “3” “0” “0” cr

Reply: “A” “1” “1” “0” “1” cr The reply indicates the following:

Unit 1 waited 40 milliseconds and then sent a reply indicating no connection of the RS-232 port to the network and the CTS handshake line is in the low state.

Unit 2 waited 60 milliseconds and then sent a reply indicating connection of the RS-232 port to the network and the CTS handshake line is in the low state.

Unit 3 waited 80 milliseconds and then sent a reply indicating no connection of the RS-232 port to the network and the CTS handshake line is in the low state.