EIR505
Quick Start Guide
Elinx Managed Ethernet Switch
EIR505 Series
1 | Items Included |
|
oEthernet Switch
oCD with Support Manual o This Quick Start Guide o Panel Mount Bracket
2
Default Settings
oIP Address: 192.168.16.1
oSubnet Mask: 255.255.255.0 o Gateway: 192.168.15.254
o User Name: root, Password: root
3 | DIP Switch Settings |
|
Pos |
|
| Statu | s |
| Description |
1 |
|
| OFF |
| Disable port 1 Alarm | |
|
| ON |
| Enable port 1 Alarm | ||
|
|
|
| (If port 1 link fails, the fault LED will light) | ||
|
|
|
|
|
| |
2 |
|
| OFF |
| Disable port 2 Alarm | |
|
| ON |
| Enable port 2 Alarm | ||
|
|
|
| (If port 2 link fails, the fault LED will light) | ||
|
|
|
|
|
| |
3 |
|
| OFF |
| Disable port 3 Alarm | |
|
| ON |
| Enable port 3 Alarm | ||
|
|
|
| (If port 3 link fails, the fault LED will light) | ||
|
|
|
|
|
| |
4 |
|
| OFF |
| Disable port 4 Alarm | |
|
| ON |
| Enable port 4 Alarm | ||
|
|
|
| (If port 4 link fails, the fault LED will light) | ||
|
|
|
|
|
| |
5 |
|
| OFF |
| Disable port 5 Alarm | |
|
| ON |
| Enable port 5 Alarm | ||
|
|
|
| (If port 5 link fails, the fault LED will light) | ||
|
|
|
|
|
| |
6 |
|
| OFF |
| Disable the ring master function | |
|
|
|
|
|
| |
|
| ON |
| Enable the switch as the ring master | ||
|
|
|
| |||
|
|
|
| in the redundant ring group. | ||
|
|
|
|
|
|
4 | LED Chart |
|
|
|
|
|
LED | Status |
| Meaning |
Power | Green |
| The switch is powered on |
Off |
| The switch is powered off | |
|
| ||
R.M. | Green |
| Ring Master (Master of a Redundant Ring) |
(Ring Master) | Off |
| The switch is not a Ring Master |
Power 1 | Green |
| Power Source 1 is available |
Off |
| Power Source 1 is unavailable | |
|
| ||
Power 2 | Green |
| Power Source 2 is available |
Off |
| Power Source 2 is unavailable | |
|
| ||
Fault | Yellow |
| Power Source Failure or Port Failure |
Off |
| Normal Operation | |
|
| ||
Link/ACT | Green |
| The port is linked |
Blinking |
| The port is receiving or transmitting packets | |
Port 5 |
| ||
Off |
| No device attached | |
|
| ||
FDX/COL | Yellow |
| Full Duplex Mode |
Blinking |
| Data Collision | |
Port 5 |
| ||
Off |
| Half Duplex Mode | |
|
|
5 | Hardware Installation |
|
|
oRecord the switch’s MAC Address in the space provided. The MAC Address is printed on the product
label. Provide the MAC Address to your Network
Administrator. The Network Administrator should provide an IP Address, Subnet Mask, and Gateway.
oSelect a mounting location and install with the attached DIN rail clip or included panel mount kit.
oConnect power to the switch o 12 to 48 VDC
o Redundant DC input is available with fault contacts.
International Headquarters: 707 Dayton Road PO Box 1040 Ottawa, IL 61350 USA
European Headquarters: Westlink Commercial Park Oranmore Co. Galway Ireland +353 91 792444 Fax +353 91 792445