Automatic Lift Fryer

Maintenance

10.Before draining the cleaning solution, remove the filter bag, screen and pipe connections from the filter vat. This must be done before draining the cleaning solution. NEVER pump water or detergent through the filter system.

11.After 15 minutes, slowly open the drain valve. Drain the solution into the filter vat and discard.

12.Rinse the pot with hot water, using the pot brush to remove remaining sediment, drain and discard.

13.Close the drain and refill the fryer pot with hot water to the proper level.

14.Add approximately 4 to 6 ounces of distilled (white) vinegar to develop a neutralizing solution. Stir the solution briefly. Leave in the pot for three to five minutes and discard. NOTE: Foaming of shortening after boil-outs is caused by failure to follow proper neutralizing procedures.

15.Repeat steps 12 through 14 as needed to remove all traces of cleaning solution.

16.Rinse the pot again with Cool water, drain and discard.

Damage to the fryer could result if the fryer pot is not completely dry before filling with shortening. Refill the fryer pot with shortening ONLY when it is completely dry.

17.Dry the fryer pot and filter vat COMPLETELY.

18.Close the main drain and fill with new shortening to the proper level.

27

Page 29
Image 29
Bakers Pride Oven ALF-FC service manual Automatic Lift Fryer Maintenance