EXTRACTION
Extraction is not a specific requirement for this type of appliance.
Certain conditions e.g.
Installation in a confined space, temperature controlled environment, continuous use or high volume production cooking may require the need for ventilation or extraction.
Consult your local Ventilation/Extraction, Air conditioning company or contact the Technical Services Department at BKI.
ELECTRICAL CONNECTION
This appliance requires a 230V,50Hz single phase + Neutral + Earth power Supply.
WARNING - THIS APPLIANCE MUST BE EARTHED
•Each appliance is despatched with an electrical test certificate.
•Check the details shown on the appliance data rating plate against the cer- tificate supplied.
•Check that the voltage shown on the data plate and test certificate con- forms with your power supply.
If the details do not conform contact the Technical Services Department at BKI
BKI Europe |
|
Theale Technology Centre |
|
Station Road |
|
Theale |
|
Reading |
|
West Berkshire |
|
RG7 4AA |
|
Tel: (44) 0870 990 4242 |
|
Fax: (44) 0870 990 4243 | Web: www.bkideas.com |
| 6 |
Safety Cut-Out - Re-Set Button
If the safety thermal
•Turn the mains switch `OFF`, disconnect oven from mains power supply.
•Refer to the relevant wiring diagram and check all components and con- trols before
•The safety thermal
1.Remove the two side panel securing screws, slide the panel `Up` and `Out` at the bottom.
2.The safety thermal
3.Press hard on the `Red`
4.Replace side panel and check oven operation.
WARNING:
REPEATED OPERATION OF THE SAFETY THERMAL
SERIOUS DAMAGE WILL OCCUR IF THE CAUSE IS NOT IDENTIFIED AND RECTIFIED.
11