RoadRunners Evolution –L (1D) & -LA (Laser) – Programming Guide v1.5 - 13 -
Data Capture
for Workforce
in Motion
1.5. The different connection methods
There are two (2) different way to create a connection from a Host and a scanner:
- Slave mode (by default)
The Host (PC, BaracodaManager, …) is creating the connection onto the scanner.
- Master mode
The scanner is creating itself a connection to the recorded Host Blu etooth address. This connection
attempt is set after a scan of barcode. The configuration of Host address (on which the scanner will set
up a connection) can be done:
o Via BaracodaManager software.
o Via scan of barcodes.
All usage mode (Real Time, No Data Loss, Batch) are obviously available on th ose two different ways of
connection.
The configuration of the Host Bluetooth address (BDA) i s made by scanning the 0-9, a-f, A-F labels (Appendix 1)
as on a calculator; following the timestamp format shown above.
For example: to set the following BDA: 00:c3:EF:44:a2:B9, the user will scan:
- “Set Remote BDA” label,
- “0” label,
- “0” label,
- “c” label,
- “3” label,
- “E” label,
- “F” label,
- “4” label,
- “4” label,
- “a” label,
- “2” label,
- ���B” label,
- “9” label,
- “End of Config” label.
\ V T \ VT Z \ NUL \ SOH\ SOH\ FF \ FF
Enabl e master mode
\ V T \ VT Z \ NUL \ SOH\ NUL \ FF \ FF
Disab l e mast er mode
\ VT\ VT Z\ NUL\ ST X\ SOH\ SOH\ FF\ F F
Enabl e master mode and di scon nect
\ VT\ VT Z\ NUL\ ST X\ NUL\ SOH\ F F\ FF
Disa ble mast er mode and di sconnect
\ V T \ VT ^ \ NUL \ SOH \ ENQ\ LF \ LF
Set Remote BDA
\ L F \ L F E N D \ F F \ F F
End of Conf i g