5. Connections

TheCLM R10+ is standard equipped with one 5 cable input module and one DVI input module.

5.3 Communication connections

Communication interface

1 2
3
RS232 / 422 OUT RS232 / 422 INUSB
DIAGNOSTIC CODE IR RECEIVER
STBY / ON
OK REC
WARNING IR
10/100 ACT
10/100
BASE-T
IN OUT
DMX
REMOTE
CTRL
A
B
C
D
E
F
G
H
I
J
K
L
M
Image5-10
Communicationconnections
A Projectorstatus LED
B Warning LED
C IRsignal acknowledged LED
D IRsignal received LED
E Ethernetport
F DMXin port
G DMXout port
H USBport
I RS232/422 output port
J RS232/422 input port
K XLRinput port for remote control
L IR receiver
M Twodigit7-segment display for diagnostic code

Projector status

The projector “status” LED (A) lightsup gr een whilein operation. The same LED lights up red when the projector is switched to

standby.

Besidesthe projectorstatus LED (A) the communication interface has also a “warning” LED (B) which blinks in case the projector

encounters an internal problemco ncerningfan speed, temperature, supply voltages, ... etc. These type of problems still allows

the projector to operate (the show can go on) but an action will be required within a short time period. More information about the

involvedproblem isgiven on the local LCD display of the projector.

A two character 7-segment display (M) shows, during normaloper ation, theselec tedinput slot number. Ifan error has occurred

then anerror code appears on this two digit display.

42 R59770021 CLMR10+ 11/10/2010