E. Troubleshooting
E. TROUBLESHOOTING

E.1 Error codes

Overview
Whenthe error code is preceded by a ’-’ sign, then the error means a real error for the projector.
Whenthe error code is preceded by a ’+’ sign, then the error code means a warning. The projector does not fail yet, but take care
forthe warning and try to resolve the problem. Awarning state can turn into an error state.
Notall error codes can have two states. Whenthe state is available, it is indicated by a Yes in the overview table. When the state
is not available, it is indicated by a No.
Error
code
Description Error Warning Caused by Action
1001 Wronglam p 1
parameters
Yes -Wrong lamp/ no communication
with lamp
Check lamp type
Calla qualied service engineer
1002 Wronglam p 2
parameters
Yes -Wrong lamp/ no communication
with lamp
Check lamp type
Calla qualied service engineer
1003 Wronglam p 3
parameters
Yes -Wrong lamp/ no communication
with lamp
Check lamp type
Calla qualied service engineer
1004 Wronglam p 4
parameters
Yes -Wrong lamp/ no communication
with lamp
Check lamp type
Calla qualied service engineer
1011 Lamp1 missing Yes Yes Nolamp inserted in position 1 Insert a lamp in position 1
1012 Lamp2 missing Yes Yes Nolamp inserted in position 2 Insert a lamp in position 2
1013 Lamp3 missing Yes Yes Nolamp inserted in position 3 Insert a lamp in position 3
1014 Lamp4 missing Yes Yes Nolamp inserted in position 4 Insert a lamp in position 4
1021 Lamp1 broken Yes -Lamp 1is not ON Check installation of lamp 1
(connection,cable, etc.)
1022 Lamp2 broken Yes -Lamp 2is not ON Check installation of lamp 2
(connection,cable, etc.)
1023 Lamp3 broken Yes -Lamp 3is not ON Check installation of lamp 3
(connection,cable, etc.)
1024 Lamp4 broken Yes -Lamp 4is not ON Check installation of lamp 4
(connection,cable, etc.)
1399 I²Copen error Yes
1398 I²Cread error Yes
1397 I²Cwrite error Yes
1699 Formatterbusy
1697 Formatter init
failed
Yes -no communication with formatter
ctrl
Calla qualied service engineer
1696 Formatter ctrl
init failed
Yes -no communication with formatter
ctrl
Calla qualied service engineer
1695 Formatterstart
failed
Yes -no communication with formatter Call a qualied serviceengineer
1693
1692
1691
2100 LPS 1 error Yes -Replace LPS
2400 LPS 2 error Yes -Replace LPS
2700 LPS 3 error Yes -Replace LPS
3000 LPS 4 error Yes -Replace LPS
R59770021 CLM R10+ 11/10/2010 203