Desa VF-30P-PJD, VF-30N-PJD, VF-24N-PJD, VF-24P-PJD, VF-18N-PJD, VF-18P-PJD troubleshooting

Models: VF-30N-PJD VF-30P-PJD, VF-30N-PJD, VF-24N-PJD, VF-24P-PJD, VF-18N-PJD, VF-18P-PJD

1 32
Download 32 pages 5.08 Kb
Page 21
Image 21
troubleshooting

troubleshooting

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Burner backfiring during com-

1.

Burner orifice is clogged or

1.

Clean burner (see Cleaning

 

bustion

 

damaged

 

and Maintenance, page 19) or

 

2.

Damaged burner

2.

replace burner orifice

 

Replace damaged burner

 

3.

Gas regulator defective

3.

Replace gas regulator

 

 

 

 

 

 

Orange flame in burner during

1.

Not enough air

1.

Check burner for dirt and

burner combustion

 

 

 

debris. If found, clean burner

 

 

 

 

(see Cleaning and Mainte-

 

2.

Gas regulator defective

2.

nance, page 19)

 

Replace gas control

 

 

 

 

 

 

Slight smoke or odor during

1.

Residues from manufacturing

1.

Problem will stop after a few

initial operation (first hour)

 

processes and logs curing

 

hours of operation

 

 

 

 

 

 

Heater produces awhistling noise

1.

Turning control knob to HI

1.

Turn control knob to LO

when burner is lit

2.

position when burner is cold

 

position and let warm up for

 

Air in gas line

2.

a minute

 

 

 

Operate burner until air is

 

 

 

 

removed from line. Have gas

 

 

 

 

line checked by local natural

 

3.

Air passageways on heater

3.

or propane/LP gas company

 

Observe minimum installation

 

4.

blocked

4.

clearances (see page 9)

 

Dirty or partially clogged

Clean burner (see Cleaning

 

 

burner orifice(s)

 

and Maintenance, page 19) or

 

 

 

 

replace burner orifice

 

 

 

 

 

 

White powder residue forming

1.

When heated, vapors from

1.

Turn heater off when using

within burner box or on adjacent

 

furniture polish, wax, carpet

 

furniture polish, wax, carpet

walls or furniture

 

cleaners, etc. may turn into

 

cleaners or similar products

 

 

white powder residue

 

 

 

 

 

 

 

 

 

Moisture/condensation noticed

1.

Not enough combustion/ven-

1.

Refer to Air for Combustion

on windows

 

tilation air

 

and Ventilation requirements

 

 

 

 

(page 5)

111826-04C

www.desatech.com

21