Set Timer

Operating Heater

Continued

Set Timer

 

 

 

 

 

• Switch to timer mode by pressing the SET

 

button briefly.

 

 

 

 

 

Press the SET button until P1

 

 

 

flashes.

 

 

 

 

Set the hours with

and minutes with .

Press SET briefly for the next burner cycle time.

If all 4 times are set, pressing the OFF button or waiting will complete the programming.

to turn gas off

to appliance

Shutting Off Heater

Press OFF button on remote control to switch off main gas and pilot gas.

Shutting Off Burner Only (pilot stays lit) Press to decrease the flame height and shut off main burner.

MANUAL LIGHTING

Procedure

Shutting Off Heater WARNING: Manual lighting must be performed by a qualified service person.

The system has a "MANUAL OVERRIDE" feature that allows you to light with a match.

Lighting with a Match

1. STOP! Read the safety information on page 14.

2. Make sure equipment shutoff valve is fully open.

3. Turn motor-knob clockwise to Lighting with a Match to OFF position.

4. Wait (5) minutes to clear any gas and then smell for gas around heater and near floor. If you smell gas, STOP! follow "B" on page 14. If you do not smell gas, go to the next step.

5. Make sure ON/OFF switch is in "–" (ON) position.

6. MAN knob (valve) in MAN position, a metallic core is visible. (see Figure 17).

7. Push and hold down metal core fully by using a dull object such as a pen. This lets the pilot gas flow.

8. Light pilot burner with a match, (see Figure 18).

9.Continue holding down metal core for about

10 seconds. Pilot should stay lit after releas- ing metal core. If not, repeat step 1 thru 4.

10.Turn MAN knob to ON position. This lets main gas flow.

11.Turn motor knob to adjust flame. Knob has a slipping clutch that allows manual flame height adjustment as well as adjustment to pilot gas.

Lighting with Piezo Ignitor

 

1.

Disconnect ignitor cable from receiver and

 

connect to Piezo Ignitor Tab (see Figure 17

 

and Wiring Diagram on page 23).

 

2.

STOP! Read safety information on page 14,

3.

Make sure equipment shutoff valve is fully

 

open.

 

4.

Turn motor knob clockwise

to the

 

OFF position.

 

5.

Wait (5) minutes to clear any gas and then

 

smell for gas around heater and near floor. If

 

you smell gas, STOP! follow "B" on page 14.

6.

ON/OFF switch in "—" ON position.

7.

MAN-knob on valve is in MAN position (see

 

Figure 17), When in MAN position you can

 

see a metallic core.

 

8.

Push and hold down metal core fully with

 

a pen while the pilot gas flows.

 

9.

Press and release piezo ignitor button until

 

pilot lights.

 

Piezo

Metalic

MAN Knob

Motor

Core for

Knob

Ignitor

Manual

in Manual

in ON

Tab

Ignition

Position

Position

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Piezo Ignitor Lighting with Piezo Ignitor Microswitch

ON/OFF Switch

Figure 17 - PJD Control Valve

Figure 18 - Pilot

111826-04C

www.desatech.com