Troubleshooting
WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater.
CAUTION: Never use a wire, needle or similar object to clean ODS/pilot. This can damage ODS/pilot unit.
Note: All troubleshooting items are listed in order of operation.
OBSERVED PROBLEM | POSSIBLE CAUSE | REMEDY | ||||
|
|
|
|
|
| |
When | and | are pressed | 1. Ignitor electrode not con- | 1. | Reconnect ignitor cable | |
at the same time, there is no spark |
| nected to ignitor cable | 2. | Free ignitor cable if pinched | ||
at ODS/pilot |
| 2. Ignitor cable pinched or wet | ||||
|
|
|
|
|
| by any metal or tubing. Keep |
|
|
| 3. | Broken ignitor cable | 3. | ignitor cable dry |
|
|
| Replace ignitor cable | |||
|
|
| 4. | Bad piezo ignitor | 4. | Replace piezo ignitor |
|
|
| 5. | Ignitor electrode positioned | 5. | Replace pilot assembly |
|
|
| 6. | wrong or broken | 6. | Replace module |
|
|
| Bad module | |||
When | and | are pressed, | 1. Gas supply turned off or equip- | 1. | Turn on gas supply or open | |
there is spark at ODS/pilot but |
| ment shutoff valve closed | 2. | equipment shutoff valve | ||
no ignition |
|
| 2. Control knob not in PILOT | Turn control knob to PILOT | ||
|
|
| 3. | position | 3. | position |
|
|
| Control knob not pressed in | Press in control knob while in | ||
|
|
| 4. | while in PILOT position | 4. | PILOT position |
|
|
| Air in gas lines when in- | Continue holding down con- | ||
|
|
|
| stalled |
| trol knob. Repeat igniting op- |
|
|
| 5. | Depleted gas supply (pro- | 5. | eration until air is removed |
|
|
| Contact local propane/LP gas | |||
|
|
| 6. | pane/LP only) | 6. | company |
|
|
| ODS/pilot is clogged | Clean ODS/pilot (see Cleaning | ||
|
|
|
|
|
| and Maintenance, page 19) or |
|
|
| 7. | Gas regulator setting is not | 7. | replace ODS/pilot assembly |
|
|
| Replace gas regulator | |||
|
|
| 8. | correct | 8. | Replace module |
|
|
| Bad module | |||
Burner does not light after pilot | 1. Inlet gas pressure is too low | 1. | Contact local natural or pro- | |||
is lit |
|
| 2. | Burner orifice(s) clogged | 2. | pane/LP gas company |
|
|
| Clean burner (see Cleaning | |||
|
|
|
|
|
| and Maintenance, page 19) or |
|
|
| 3. | Burner orifice(s) diameter is | 3. | replace burner orifice(s) |
|
|
| Replace burner orifice(s) | |||
|
|
| 4. | too small | 4. | Reconnect leads (see Wiring |
|
|
| Wire disconnected from gas | |||
|
|
| 5. | control | 5. | Diagram, page 24) |
|
|
| Bad module | Replace module | ||
Delayed ignition burner | 1. Manifold pressure is too low | 1. | Contact local natural or pro- | |||
|
|
| 2. | Burner orifice(s) clogged | 2. | pane/LP gas company |
|
|
| Clean burner (see Cleaning | |||
|
|
|
|
|
| and Maintenance, page 19) or |
|
|
|
|
|
| replace burner orifice |
20 | www.desatech.com |