Bard W24A to W70A, W24L to W70L manual Electrical Specifications

Models: W24A to W70A W24L to W70L

1 8
Download 8 pages 31.04 Kb
Page 5
Image 5
Electrical Specifications

Electrical Specifications

 

 

Rated

Operating

No. Field

2 Minimum

1 Maximum

 

Model

Volts

Voltage

Power

Circuit

External Fuse

 

 

 

and Phase

Range

Circuits

Amps

or Circuit Breaker

 

W24A1

- D0Z

 

 

1

16

20

 

 

D05

240/220-1

198-254

1

28

30

 

 

D08

 

 

1

44

45

 

 

 

 

 

 

 

 

 

W24A1

- F0Z

415/380-3 3

342-456

1

9

15

 

W24L1

F05

1

11

15

 

 

 

 

 

 

 

 

 

 

 

 

W30A1

- D0Z

 

 

1

23

35

 

 

D05

240/220-1

198-254

1

29

35

 

 

D10

 

 

1

55

60

 

W30A1

- F0Z

 

 

1

9

15

 

 

F07

415/380-3 3

342-456

1

15

15

 

 

F12

 

 

1

24

25

 

W36A1

- D0Z

 

 

1

24

35

 

 

D05

240/220-1

198-254

1

29

35

 

 

D10

 

 

1

55

60

 

 

 

 

 

 

 

 

W36A1 - E0Z

 

 

1

20

25

 

 

E06

220/200-3

180-242

1

24

30

 

 

E12

 

 

1

40

40

 

 

 

 

 

 

 

 

 

W36A1

- F0Z

 

 

1

11

15

 

W36L1

F07

415/380-3 3

342-456

1

16

20

 

 

F12

 

 

1

25

25

 

 

 

 

 

 

 

 

 

W42A1

- E0Z

 

 

1

25

35

 

 

E09

220/200-3

180-242

1

32

35

 

 

E15

 

 

1

53

60

 

W42A1

- F0Z

 

 

1

14

20

 

W42L1

F07

415/380-3 3

342-456

1

17

20

 

 

F14

 

 

1

31

35

 

W48A1 - E0Z

 

 

1

27

35

 

 

E09

220/200-3

180-242

1

34

35

 

 

E15

 

 

1

53

50

 

 

 

 

 

 

 

 

 

W48A1

- F0Z

 

 

1

15

20

 

W48L1

F07

415/380-3 3

342-456

1

17

20

 

 

F14

 

 

1

31

35

 

W60A1

- E0Z

 

 

1

28

40

 

 

E09

220/200-3

180-242

1

34

40

 

 

E15

 

 

1

53

60

 

W60A1

- F0Z

 

 

1

16

20

 

W60L1

F07

415/380-3 3

342-456

1

17

20

 

 

F14

 

 

1

31

35

 

W70A1

- P0Z

 

 

1

25

35

 

W70L1

P07

400/380-3 3

342/440

1

25

35

 

 

P14

 

 

1

32

35

 

1Maximum size of the time delay fuse or "D" rated circuit breaker for protection of field wiring conductors.

2 These "Minimum Circuit Amps" values are to be used for sizing the field power conductors.

3 415/380-3 and 400/380-3 electrical ratings are 3-phase wye (star) systems requiring three (3) phase legs plus neutral and ground. NOTE: The indoor and outdoor motors and 24V transformer primary are connected at 240V derived from one (1) phase leg to neutral. This is internally connected and no field wiring required.

NOTE: All wiring must conform to NIC/EIC latest edition.

IMPORTANT: While this electrical data is presented as a guide, it is important to electrically connect properly sized fuses & conductor wires in accordance with the National Electrical Code & all local codes.

Form No.

S3408-1011

Supersedes

S3408-710

Page

5 of 8