Bard W24L to W70L, W24A to W70A manual W 36 A, Air Conditioning Control Modules

Models: W24A to W70A W24L to W70L

1 8
Download 8 pages 31.04 Kb
Page 8
Image 8
W 36 A 1

Air Conditioning Wall-Mount Model Nomenclature

W 36 A 1

D

10 X

X X

X

X

X

SERIES

REVISIONKW

CONTROL MODULES (See Chart Below)

NOMINAL CAPACITY 24 - 2 Ton

30 - 2½ Ton

36 - 3 Ton

42 - 3½ Ton

48 - 4 Ton

60 - 5 Ton

70 - 6 Ton

VOLTS & PHASE D - 240/220/50/1 E - 220/200/50/3 F - 415/380/50/3 1 P - 400/380/50/3 1

 

COLOR OPTIONS

 

X - Beige (Standard)

 

1 - White

VENTILATION OPTIONS

4 - Buckeye Gray

X - Barometric Fresh Air Damper (Standard)

5

- Desert Brown

B - Blank-off Plate

8

- Dark Bronze

M - Motorized Fresh Air Damper

A - Aluminum

V - Commercial Room Ventilator-Motorized w/Exhaust

S - Stainless Steel

E - Economizer (Internal) - Fully Modulating w/Exhaust

 

 

COIL OPTIONS X - Standard

1 - Phenolic Coated Evaporator

2 - Phenolic Coated Condenser

3 - Phenolic Coated Evaporator and Condenser

OUTLET OPTIONS X - Front (Standard)

TYPE

A = Compressor & Controls - Right Side L = Compressor & Controls - Left Side

1See Electrical Specifications (Page 5).

FILTER OPTIONS

X- 1-Inch (25mm) Disposable (Standard) W - 1-Inch (25mm) Washable

P - 2-Inch (51mm) Pleated

Ventilation Options

Models

W24A1

W30A1

W42A1, W48A1, W60A1, W70A1

W24L1

W36A1, W36L1

W42L1, W48L1, W60L1, W70L1

 

Description

Factory Installed

Field Installed

Factory Installed

Field Installed

Factory Installed

Field Installed

Code No.

Part No.

Code No.

Part No.

Code No.

Part No.

 

Barometric Fresh Air Damper

X

BFAD-2

X

BFAD-3

X

BFAD-5

 

 

 

 

 

 

 

Blank-Off Plate

B

BOP-2

B

BOP-3

B

BOP-5

 

 

 

 

 

 

 

Motorized Fresh Air Damper

M

MFAD-2

M

MFAD-3

M

MFAD-5

 

 

 

 

 

 

 

Commercial Ventilator - Motorized

V

CRV-2

V

CRV-3

V

CRV-5

 

 

 

 

 

 

 

Economizer (Internal) - Fully Modulating 1

E

EIFM-2B

E

EIFM-3C

E

EIFM-5C

 

 

 

 

 

 

 

1Low ambient control is required with economizer for low temperature compressor operation.

Air Conditioning Control Modules

 

 

 

All Models Except As Noted

HPC 1

LPC 2

CCM 3

LAC 4

ALR 5

SK 6

SK 7

DDC 9

Factory Installed Code

Field Installed Part

STD

STD

STD

 

 

 

 

 

X

N/A

STD

STD

STD

￿

 

 

 

 

E

CMA-28

STD

STD

STD

￿

￿

 

 

 

J

Factory Only

STD

STD

STD

￿

 

￿

 

 

K

CMC-15 and CMA-28

STD

STD

STD

￿

￿

￿

 

 

M

Factory Only

STD

STD

STD

 

 

￿

 

 

Field Installed Only

CMC-15

STD

STD

STD

￿

￿

 

 

￿

V 9

Factory Only

STD

STD

STD

 

 

 

 

￿

Field Installed Only

CMA-23 for W18-36A

 

 

 

 

CMA-24 for W42-70A

 

 

 

 

 

 

 

 

 

STD

STD

STD

 

 

 

￿

 

Field Installed Only

SK111

STD = Standard equipment all models.

1 HPC. High pressure control is auto reset. Always used with compressor control module (CCM) which is included. See note 3. 2 LPC. Low pressure control is auto reset. Always used with compressor control module (CCM) which is included. See note 3.

3CCM. Compressor control module has adjustable 30-second to 5-minute delay-on-break timer. On initial power-up, or any time the power is interrupted, the delay-on-make will be 2 minutes plus 10% of the delay-on-break setting. There is no delay-on-make during routine operation of the unit. The module also provides the lockout feature (with 1 retry) for

high and/or low-pressure controls, and a 2-minute timed bypass for low-pressure control. 4 LAC. Low ambient control permits cooling operation down to 0°F (-17.7°C)

5 ALR. The alarm relay has a set of normally open and normally closed dry contacts to provide the ability to signal a condition of shutdown on either high or low pressure controls.

6 SK.

PTCR start kit can be used with all -A single phase models. Increases starting torque 2-3x. Not used for -E, -F or -P three phase models. Do not use if SK111 is used.

7 SK.

Start capacitor and potential relay start kit can be used with all -A single phase models. Increases starting torque 9x. Not used for -E, -F or -P three phase models. Do not

use if CMC-15 is used.

8 DDC. Incorporates 4 additional sensors: discharge air temperature, indoor blower airflow, compressor current, and dirty filter. These sensing devices function to input analog data such as temperature, as well as digital data such as airflow, compressor status or filter status.

9 “V” control module should be ordered in conjunction with direct digital controller (DDC) model TCS24. Refer to DDC specification sheet S3280 for more information.

Bard Manufacturing Company, Inc.

Bryan, Ohio 43506

www.bardhvac.com

Since 1914 . . . Moving ahead, just as planned.

Form No.

S3408-1011

Supersedes

S3408-710

Page

8 of 8

Due to our continuous product improvement policy, all specifications subject to change without notice.

Before purchasing this appliance, read important energy cost and efficiency information available from your retailer.

Form No.

S3408

October, 2011

Supersedes: S3408-710

Page 8
Image 8
Bard W24L to W70L, W24A to W70A manual W 36 A, Air Conditioning Control Modules