Air Conditioning
W 36 A 1 | D | 10 X | X X | X | X | X |
SERIES
REVISIONKW
CONTROL MODULES (See Chart Below)
NOMINAL CAPACITY 24 - 2 Ton
30 - 2½ Ton
36 - 3 Ton
42 - 3½ Ton
48 - 4 Ton
60 - 5 Ton
70 - 6 Ton
VOLTS & PHASE D - 240/220/50/1 E - 220/200/50/3 F - 415/380/50/3 1 P - 400/380/50/3 1
| COLOR OPTIONS | |
| X - Beige (Standard) | |
| 1 - White | |
VENTILATION OPTIONS | 4 - Buckeye Gray | |
X - Barometric Fresh Air Damper (Standard) | 5 | - Desert Brown |
B - | 8 | - Dark Bronze |
M - Motorized Fresh Air Damper | A - Aluminum | |
V - Commercial Room | S - Stainless Steel | |
E - Economizer (Internal) - Fully Modulating w/Exhaust |
|
|
COIL OPTIONS X - Standard
1 - Phenolic Coated Evaporator
2 - Phenolic Coated Condenser
3 - Phenolic Coated Evaporator and Condenser
OUTLET OPTIONS X - Front (Standard)
TYPE
A = Compressor & Controls - Right Side L = Compressor & Controls - Left Side
1See Electrical Specifications (Page 5).
FILTER OPTIONS
X-
P -
Ventilation Options
Models | W24A1 | W30A1 | W42A1, W48A1, W60A1, W70A1 | ||||
W24L1 | W36A1, W36L1 | W42L1, W48L1, W60L1, W70L1 | |||||
| |||||||
Description | Factory Installed | Field Installed | Factory Installed | Field Installed | Factory Installed | Field Installed | |
Code No. | Part No. | Code No. | Part No. | Code No. | Part No. | ||
| |||||||
Barometric Fresh Air Damper | X | X | X | ||||
|
|
|
|
|
|
| |
B | B | B | |||||
|
|
|
|
|
|
| |
Motorized Fresh Air Damper | M | M | M | ||||
|
|
|
|
|
|
| |
Commercial Ventilator - Motorized | V | V | V | ||||
|
|
|
|
|
|
| |
Economizer (Internal) - Fully Modulating 1 | E | E | E | ||||
|
|
|
|
|
|
|
1Low ambient control is required with economizer for low temperature compressor operation.
Air Conditioning Control Modules |
|
|
| All Models Except As Noted | |||||
HPC 1 | LPC 2 | CCM 3 | LAC 4 | ALR 5 | SK 6 | SK 7 | DDC 9 | Factory Installed Code | Field Installed Part |
STD | STD | STD |
|
|
|
|
| X | N/A |
STD | STD | STD |
|
|
|
| E | ||
STD | STD | STD |
|
|
| J | Factory Only | ||
STD | STD | STD |
|
|
| K | |||
STD | STD | STD |
|
| M | Factory Only | |||
STD | STD | STD |
|
|
|
| Field Installed Only | ||
STD | STD | STD |
|
| V 9 | Factory Only | |||
STD | STD | STD |
|
|
|
| Field Installed Only | ||
|
|
|
| ||||||
|
|
|
|
|
|
|
|
| |
STD | STD | STD |
|
|
|
| Field Installed Only | SK111 |
STD = Standard equipment all models.
1 HPC. High pressure control is auto reset. Always used with compressor control module (CCM) which is included. See note 3. 2 LPC. Low pressure control is auto reset. Always used with compressor control module (CCM) which is included. See note 3.
3CCM. Compressor control module has adjustable
high and/or
5 ALR. The alarm relay has a set of normally open and normally closed dry contacts to provide the ability to signal a condition of shutdown on either high or low pressure controls.
6 SK. | PTCR start kit can be used with all |
7 SK. | Start capacitor and potential relay start kit can be used with all |
use if
8 DDC. Incorporates 4 additional sensors: discharge air temperature, indoor blower airflow, compressor current, and dirty filter. These sensing devices function to input analog data such as temperature, as well as digital data such as airflow, compressor status or filter status.
9 “V” control module should be ordered in conjunction with direct digital controller (DDC) model TCS24. Refer to DDC specification sheet S3280 for more information.
Bard Manufacturing Company, Inc.
Bryan, Ohio 43506
www.bardhvac.com
Since 1914 . . . Moving ahead, just as planned.
Form No. | |
Supersedes | |
Page | 8 of 8 |
Due to our continuous product improvement policy, all specifications subject to change without notice.