TABLE 3

Electrical Specifications — W*RV / W*LV Series

 

Electrical

 

 

 

 

 

 

 

 

 

Dual Circuit

 

 

 

 

 

 

 

 

 

 

 

 

Rating:

No. Field

3 Minimum

1 Maximum

2 Field

 

 

3 Minimum

 

 

1 Maximum

 

 

2 Field

 

 

2 Ground

 

 

Volts

2 Ground

 

 

Circuit

 

 

 

 

Power

 

 

 

Model

Power

Circuit

Overcurrent

Power

 

 

 

Overcurrent Protection

 

 

 

Wire Size

 

Hz

Wire

 

 

Ampacity

 

 

Wire Size

 

 

 

 

Circuits

Ampacity

Protection

Wire Size

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Phase

 

Ckt. A

 

Ckt. B

 

Ckt. C

Ckt. A

 

Ckt. B

 

Ckt. C

Ckt. A

Ckt. B

Ckt. C

Ckt. A

Ckt. B

 

Ckt. C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W3RV1 / W3LV1-R0Z

230/208-60-1

1

28

35

8

10

N/A

 

N/A

 

N/A

N/A

 

N/A

 

N/A

N/A

N/A

N/A

N/A

N/A

 

N/A

R05

1

54

60

6

10

N/A

 

N/A

 

N/A

N/A

 

N/A

 

N/A

N/A

N/A

N/A

N/A

N/A

 

N/A

220/200-50-1

 

 

 

 

 

R10

1 or 2

80

80

4

8

54

 

26

 

N/A

60

 

30

 

N/A

6

10

N/A

10

10

 

N/A

 

 

 

 

 

 

W3RV1 / W3LV1-S0Z

230/208-60-3

1

19

30

10

10

N/A

 

N/A

 

N/A

N/A

 

N/A

 

N/A

N/A

N/A

N/A

N/A

N/A

 

N/A

S06

1

37

40

8

10

N/A

 

N/A

 

N/A

N/A

 

N/A

 

N/A

N/A

N/A

N/A

N/A

N/A

 

N/A

220/200-50-3

 

 

 

 

 

S09

1

46

50

8

10

N/A

 

N/A

 

N/A

N/A

 

N/A

 

N/A

N/A

N/A

N/A

N/A

N/A

 

N/A

 

 

 

 

 

 

W3RV1 / W3LV1-T0Z

460-60-3

1

12

15

14

14

N/A

 

N/A

 

N/A

N/A

 

N/A

 

N/A

N/A

N/A

N/A

N/A

N/A

 

N/A

T09

1

25

25

10

10

N/A

 

N/A

 

N/A

N/A

 

N/A

 

N/A

N/A

N/A

N/A

N/A

N/A

 

N/A

400-50-3

 

 

 

 

 

T12

1

29

30

10

10

N/A

 

N/A

 

N/A

N/A

 

N/A

 

N/A

N/A

N/A

N/A

N/A

N/A

 

N/A

 

 

 

 

 

 

W5RV1 / W5LV1-R0Z

230/208-60-1

1

39

60

8

10

N/A

 

N/A

 

N/A

N/A

 

N/A

 

N/A

N/A

N/A

N/A

N/A

N/A

 

N/A

R10

1 or 2

91

100

3

8

39

 

52

 

N/A

60

 

60

 

N/A

8

6

N/A

10

10

 

N/A

220/200-50-1

 

 

 

 

 

R20

1 or 3

143

150

10

6

39

 

52

 

52

60

 

60

 

60

8

6

6

10

10

 

10

 

 

 

 

 

 

W5RV1 / W5LV1-S0Z

230/208-60-3

1

28

40

8

10

N/A

 

N/A

 

N/A

N/A

 

N/A

 

N/A

N/A

N/A

N/A

N/A

N/A

 

N/A

S09

1

55

60

6

10

N/A

 

N/A

 

N/A

N/A

 

N/A

 

N/A

N/A

N/A

N/A

N/A

N/A

 

N/A

220/200-50-3

 

 

 

 

 

S18

2

N/A

N/A

N/A

N/A

55

 

28

 

N/A

60

 

30

 

N/A

6

10

N/A

10

10

 

N/A

 

 

 

 

 

 

W5RV1 / W5LV1-T0Z

460-60-3

1

18

25

10

10

N/A

 

N/A

 

N/A

N/A

 

N/A

 

N/A

N/A

N/A

N/A

N/A

N/A

 

N/A

T09

1

32

35

8

10

N/A

 

N/A

 

N/A

N/A

 

N/A

 

N/A

N/A

N/A

N/A

N/A

N/A

 

N/A

400-50-3

 

 

 

 

 

T18

1

41

45

8

10

N/A

 

N/A

 

N/A

N/A

 

N/A

 

N/A

N/A

N/A

N/A

N/A

N/A

 

N/A

 

 

 

 

 

 

W6RV1 / W6LV1-S0Z

230/208-60-3

1

42

60

8

10

N/A

 

N/A

 

N/A

N/A

 

N/A

 

N/A

N/A

N/A

N/A

N/A

N/A

 

N/A

S09

2

N/A

N/A

N/A

N/A

42

 

28

 

N/A

60

 

30

 

N/A

8

10

N/A

10

10

 

N/A

220/200-50-3

 

 

 

 

 

S18

2

N/A

N/A

N/A

N/A

42

 

55

 

N/A

60

 

60

 

N/A

8

6

N/A

10

10

 

N/A

 

 

 

 

 

 

W6RV1 / W6LV1-T0Z

460-60-3

1

22

35

8

10

N/A

 

N/A

 

N/A

N/A

 

N/A

 

N/A

N/A

N/A

N/A

N/A

N/A

 

N/A

T09

1

36

45

8

10

N/A

 

N/A

 

N/A

N/A

 

N/A

 

N/A

N/A

N/A

N/A

N/A

N/A

 

N/A

400-50-3

 

 

 

 

 

T15

1

45

50

8

10

N/A

 

N/A

 

N/A

N/A

 

N/A

 

N/A

N/A

N/A

N/A

N/A

N/A

 

N/A

 

 

 

 

 

 

1Maximum size of the time delay fuse or HACR type circuit breaker for protection of field wiring conductors.

2 Based on 75C copper wire. All wiring must conform to the National Electrical Code and all local codes.

3 These “Minimum Circuit Ampacity” values are to be used for sizing the field power conductors. Refer to the National Electrical code (latest version), Article 310 for power conductor sizing.

Caution: When more than one field power circuit is run through one conduit, the conductors must be derated. Pay special attention to note 8 of Table 310 regarding Ampacity Adjustment Factors when more than three (3) current carrying conductors are in a raceway.

* Top outlet supply option is available only factory installed and only on the selected models.

IMPORTANT: While this electrical data is presented as a guide, it is important to electrically connect properly sized fuses and conductor wires in accordance with the National Electrical Code and all local codes.